Draka UC900 Cat.7 S/FTP 23AWG LSZH

Standard, Solid, 23AWG, Screened

Construction
Conductor Bare copper wire, Nom. ∅ 0.56 mm (AWG 23)
Insulation Foamskin PE
Twisting 2 cores to the pair
Pair Screen Al-laminated plastic foil
Cable Lay Up 4 pairs (PiMF) to the core
Screen Copper braid, tinned
Sheath LSZH Blue
Outer Diameter Nom. 7.5mm
Weight Nom. 52 kg/km
Mechanical properties
Bending radius without load ≥ 8 X OD
with load ≥ 4 X OD
Temperature range during operation -20°C to + 60°C
during installation 0°C to + 50°C
Electrical properties at 20°C ± 5°C
DC Loop resistance ≤ 149.4Ω/km
Resistance unbalance ≤ 2%
Insulation resistance (500 V) ≥ 5000 MΩ/km
Capacitance Unbalance (Pair/Ground) ≤ 1500 pF/km
Characteristic impedance (1-100 MHz)  100 ± 5 Ω
(100 – 250) MHz  100 ± 10 Ω
(250 – 600) MHz  100 ± 15 Ω
Delay skew ≤ 25 ns/100m
Test voltage (DC, 1 min) core/core and
core/screen
1000 V
Coupling attenuation ≥ 80 dB
Max. Attenuation @ 600 Mhz 50.1 dB
Max. NEXT @ 600 Mhz 60.7 dB
Max. ACR-F @ 600 Mhz 38.4 dB
Max. Return Loss @ 600 Mhz 17.3 dB
Max. TCL @ 600 Mhz 12.2 dB

Application

  • Primary (Campus)
  • Secondary (Riser)
  • Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;10GBase-T
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM

Standards

  • IEC 61156-1 & 5
  • EN 50288-4-1

Flame Resistance

  • LSZH IEC 60332-1
Ordering Information
SAP IC UC P/N Product Description P.U
60101091 73075BL-5H Draka UCDATA CATEGORY CABLE UC900 CAT.7 SFTP 4 PAIR 23AWG BLUE IEC 60332-1, IEC60754-1&2, IEC61034 500m/reel

FIRETUF LTFIPNWM Fire Resistance SERIES

Heavy Armoured Cable Nylon + LSZH Sheath, Chemical/Corrosive Resistant

Features

  • Central Strength Member(CSM): glass fiber reinforced plastic rod(FRP), with PE coating when needed.
  • Tube: thermoplastic material containing up to 12 optical fibres and filled with a suitable water tightness compound.
  • Fire Resistance Layer: mica tape wrapped around loose tube
  • Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
  • Core Wrapping: water-blocking tape & yarn (dry-core)
  • Inner sheath: HDPE
  • Nylon sheath: Black Nylon Polyamide 12 (PA 12)
  • Outer Armour: Galvanized Steel Wire
  • Outer Sheath: LSZH flame retardant
Technical Data
No.of Flbres 4,8,16 12,24,36,48,72 96
Design (Elements x Fibre/Tube) 6×4 6 x 12 8×12
Loose Tube/Filler – ø mm Nom. 2.3 Nom. 2.0 Nom. 2.0
CSM/sheath diameter mm Nom. 3.0 Nom. 3.0 Nom. 3.0/4.8
Outer sheath thickness mm Nom. 2.0
Cable Diameter mm Nom. 17.9 Nom. 17.9 Nom. 19.7
Cable Weight Kg.Km 531 531 624
Max installation tension N 6000
Min. bending radius mm Without Tension
15 x Cable- ø
Under Maximum Tension
30 x Cable- ø
Temperature range Installation :
-10°C->+60°C
Transport & Storage :
-40°C->+70°C
Transport & Storage:
-40°C->+70°C

Application

The cable is specially designed for harsh environments. The multilayer inner sheath HDPE/PA(nylon) withstands aggressive constituents, fluids that might occur on (petro) chemical plants, aliphatic hydrocarbon resistant. The cable which is low smoke, halogen free and flame-retardant, is suitable for installation under and above ground. – Nylon jacket provides anti-termite protection of the cable
– The steel wire armour provides anti-rodent protection
– The outer sheath is flame retardant compound to Heat & Oil and UV resistant

Flame & Fire Rating

  • IEC 60332-3-24 & IEC 60331-25
Main Characteristics
Test Standard Specified value Acceptance Criteria*
Max. tension at installation (short term) IEC 60794-1-2-E1 5000N Δ I/I fibre strain ≤ 0.6%, Δα reversible
Crush IEC 60794-1-2-E3 4000N/100mm Δα ≤ 0.15dB(SM), 0.3 dB (MM) after test
Temperature Range IEC 60794-1-2-F1 -40 -> + 70ºC Δα ≤ 0.15dB/km(SM), 0.3 dB /km(MM)
Water penetration IEC 60794-1-2-F5C sample=3m, water=1m No water leakage after 24 hour

* Values for single-mode fibres, all optical measurements performed at 1550 nm
* Values for multi-mode fibres, all optical measurements performed at 1300 nm

Ordering Information
FIRETUF LTFIPNWM SERIES FO Cable part numbers are made up using the table below.

The part number always starts with the letters LTFIPNWM to denote that it is a FIRETUF LTFIPNWM SERIES FO Cable. 

This is followed by 3 numbers which symbolizes the core quantity and then 2 letters to denote the fibre type.

Example of a FIRETUF LTFIPNWM SERIES FO Cable part number: LTFIPNWM008M1

The above example describes an OM1 (62.5um, Black Sheath)

FIRETUF LTFIPNWM SERIES FO Cable, with 8 cores.

LTFIPNWM SERIES
Core quantity
FIBER TYPE
LTFIPNWM
XXX
XX
002~096 : (2 CORES ~ 96 CORES)
SM - SingleMode
M1~M4 - MultiMode

UC Copper Patch-Cord GOLD

Premium, Stranded, LSZH

Features

  • Gold Plated Housing: To further minimise oxidation and rust
  • Fully Sealed Plug: Ensure high accuracy contacts are maintained throughout instal lation
    and operation
  • Gold Plated Contacts: 50um to maximise connections
  • Unique Boot Design: Prevents entanglement during re-insertions
  • Connector is RJ45 modular plug: clear polycarbonate UL94V-0 rated
Specification
Product Family Related Cable Description
UC C300 Class D Channel, screened Cat 5e F/UTP 26/7 AWG 4P patch cable LSZH
UC C400 Class E Channel, screened Cat 6 S/FTP 27/7 AWG 4P patch cable LSZH
UC C400 Class E Channel, unscreened Cat 6 U/UTP 24/7 AWG 4P patch cable LSZH
UC C500 Class Ea Channel, screened Cat 6a S/FTP 27/7 AWG 4P patch cable LSZH
Performance
Item Description
Flame properties – LSZH IEC 60332-1, IEC 61034, IEC 60754-1 & 2
Standards EN 50173 / 50288, ISO / IEC 11801 Amendment 2,
IEC 60603-7
Length 1m, 1.5m, 3m, 5m, other lengths upon request

Premium flexible patch cables with
unique gold plating design

  • Flexible stranded bare copper conductor
    patch cable
  • 2xRJ45 connector (TIA568-B coding)
  • Color clips or different jacket color options
  • Proven performance
  • Available in PVC or LSHF
  • Component level tested

  • Color clips for colour identification available
Ordering Information
SAP IC UC P/N UC Material Code Product Description P.U
YPGBP00474 PG9561GY-1 UC C300 PG S GY L 00100 V2 F/UTP Cat.5E GOLD Patch cord Grey LSZH 26AWG 1M 1pc/bag
YPGBP00454 PG9713GY-1 UC C400 PG SF GY L 00100 V2 S/FTP Cat.6 GOLD Patch cord Grey LSZH 27AWG 1M 1pc/bag
YPGBP00434 PG9705GY-1 UC C400 PG UU GY L 00100 V2 U/UTP Cat6 GOLD Patch cord Grey LSZH 24AWG 1M 1pc/bag
YPGBP00414 PG9205GY-1 UC C500 PG SF GY L 00100 V2 S/FTP Cat.6A GOLD Patch cord Grey LSZH 27AWG 1M 1pc/bag

Category 3 UTP Multipair

U/UTP Data Cable

Application

These cables are used as riser cable in structured cabling networks, most often between distribution frames

Standards

  • IEC 61156, ISO/IEC 11801/1995, TIA/EIA 568 – A

Flame Rating

  • PVC IEC 60332 – 1,
  • LSZH IEC 60332-1
Construction
Conductor Solid bare copper wire, diameter 0.5 mm
Insulation Polyethylene, PE
Sheath PVC Black , also available on request with LSZH
Mechanical Properties
Minimum bending radius Without load 4 x OD ( OD= outer diameter )
With load 8 x OD ( OD= outer diameter )
Temperature During operation – 20° C to + 70° C
During operation    0° C to + 50° C
Electrical Properties
DC Resistance ≤ 117 Ω/ km
Insulation DC Resistance ≤ 5000 M Ω . km
Electrical Data at 20°C
Frequency Max.Attenuation Min. NEXT Min. ELFEXT Min. Return Loss   
(MHZ) (dB)  (dB) (dB) (dB)  
4 5.6 32.3 27.0 12.0
8 8.5 27.8 20.9 12.0
10 9.7 26.3 19.0 12.0
16 13.1 23.2 14.9 10.0
Ordering Information
P/N Product Description P.U  
ISV30250GY-5H Draka MMS Special Category 3 U/UTP  2 X 0.5mm PVC 500m/drum
ISV31050GY-5H Draka MMS Special Category 3 U/UTP  10 X 0.5mm PVC 500m/drum
ISV32050GY-5H Draka MMS Special Category 3 U/UTP  20 X 0.5mm PVC 500m/drum
ISV32550GY-5H Draka MMS Special Category 3 U/UTP  25 X 0.5mm PVC 500m/drum
ISV310050GY-5H Draka MMS Special Category 3 U/UTP  100 X 0.5mm PVC 500m/drum

LTFPNWM Flame Retardant SERIES

Heavy Armoured Cable Nylon + LSZH Sheath, Chemical/Corrosive Resistant

 

Application

  • The cable is specially designed for harsh environments. The multilayer inner sheath HDPE/PA(nylon) withstands aggressive constituents, fluids that might occur on (petro) chemical plants, aliphatic hydrocarbon resistant. The cable which is low smoke, halogen free and flame-retardant, is suitable for installation under and above ground. – Nylon jacket provides anti-termite protection of the cable
    – The steel wire armour provides anti-rodent protection
    – The outer sheath is flame retardant compound to Heat & Oil and UV resistant

Flame Rating

  • IEC 60332-3-22

Features

  • Central Strength Member(CSM): glass fiber reinforced plastic rod(FRP)
  • Tube: thermoplastic material containing up to 12 optical fibres and filled with a suitable water tightness compound.
  • Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
  • Core Wrapping: water-blocking tape & yarn (dry-core)
  • Inner sheath: HDPE
  • Nylon sheath: Black Nylon Polyamide 12 (PA 12)
  • Outer Armour: Galvanized Steel Wire
  • Outer Sheath: LSZH flame retardant
Configuration
No. of Flbers   4,8,12,24 32 36,48,72
Design (Elements x Fibre/Tube)   6×4 6×8 6×12
Loose Tube/Filler – ø mm Nom. 2.1 Nom.2.1 Nom. 2.1
CSM/sheath diameter mm Nom. 2.3 Nom. 2.3 Nom. 2.3
Outer sheath thickness mm Nom. 2.0
Cable Diameter mm Nom. 16.4 Nom.16.4 Nom. 16.4
Cable Weight kg.km 436 436 436
Max installation tension N 5000
Min. bending radius ( Without Tension) mm 15 x Cable ø
Min. bending radius ( Under Max. Tension)   25 x Cable ø
Main Mechanical and Environmental characteristics  
Test Standard Specified value Acceptance Criteria*  
Max. Tension IEC 60794-1-2-E1 See Configuration
Δ I/I fibre strain ≤ 0.6%,
Δα reversible
 
Crush IEC 60794 1-2-E3 4000 N/100 mm; reversible
Δα ≤ 0.15dB(SM), 0.3 dB (MM)
after test
 
Water penetration IEC 60794 1-2-F5C Sample=3m,water column=1m
No water leakages after 24hours
 
Temperature Range Transportation & Storage -40° C to +70 ° C  
Installation -10° C to + 70° C  
Operation -40° C to +70 ° C  
* Values for single-mode fibres, all optical measurements performed at 1550 nm
* Values for multi-mode fibres, all optical measurements performed at 1300 nm
 
Ordering Information
LTFPNWM SERIES FO Cable part numbers are made up using the table below.
The part number always starts with the letters LTFPNWM to denote that it is a LTFPNWM SERIES FO Cable.
This is followed by 3 numbers which symbolizes the core quantity and then 2 letters to denote the fibre type.
Example of a LTFPNWM SERIES FO
Cable part number: LTFPNWM008M1

The above example describes an OM1 (62.5um, Black Sheath) LTFPNWM SERIES FO Cable, with 8 cores.
 

 

LTFIPNWM SERIES Core Qty FIBRE TYPE  
LTFPNWM XXX
                XX
 
 
012-12 CORES
016-16 CORES
024-24 CORES
048-48 CORES
096-96 CORES

 

SM-SINGLEMODE, G652D, 9µm
M1-OM1, 62.5µm
M2-OM2, 50µm
M3-OM3, 50 µm
M4-OM4, 50µm
 
 

 

 

Draka Fire Resistant UC500 Cat.6a SFTP GSWB LSFRZH

Cat.6a 23AWG GSWB SFTP LSZH with circuit integrity behaviour

Application

  • Primary(Campus), Secondary(Riser), Tertiary(Horizontal)
  • IEEE 802.3: 10G Base-T
  • IEEE 802.5 16 MB; ISDN; TP DDI;ATM

Standards

  • ANSI/TIA-568.2-D
  • ISO/IEC 11801-1/2
  • IEC61156-5

Flame & Fire Rating

  • IEC 60331-23, IEC60332-1, IEC60332-3-24
Construction
Conductor Solid copper wire, (AWG 23)
Insulation Foam PE with special fire barrier tape
Twisting 2 cores to the pair
Screen Individual Pair Screen + Tinned Copper Braid Screen
Sheath LSZH with ATARUV
Tensile force 100 N
Mechanical Properties
Bending radius without load ≥ 16 x OD
with load ≥ 8 x OD
Temperature range during operation -15°C to + 60°C
during installation   0°C to + 50°C
Electrical Properties
DC Loop resistance ≤ 187.6 Ω/km
Impedance 1-100MHz  Nom. 100 Ω
DC Resistance unbalance ≤ 4%
Mutual capacitance at 1kHz ≤ 5.6 nF/100m
Ordering Information
P/N Product Description P.U
85048FRBRTVBK-3H  Draka UCDATA Category Cable UC500 CAT.6A SFTP 4 PAIR 23AWG GSWB LSFRZH FR ATARUV 305m/drum

MAX-FOH Flexible PAGA & Control Cable

Public Address General Alarm, Data Control Cable, Fire Resistance

Fire Characteristics
Conductor Grade A Copper specially protected by fire barrier tape to ensure circuit integrity in fire situations.
Construction Twisted pair for better signal transmission.
Core Insulation Cross-linked PE, XLPE
Outer Sheath LSZH in accordance to IEC 61034, IEC 60754-1 & 2.
Main Characteristics
Nominal overall diameter mm As per Technical Datasheet
Nominal weight (completed cable) Kg/km As per Technical Datasheet
Min bending radius mm As per Technical Datasheet
Max pulling tension kgf As per Technical Datasheet
Max conductor resistance @ 20°C Ω/km As per Technical Datasheet
Min insulation resistance @ 20°C MΩ/km As per Technical Datasheet
Dielectric withstand test kV/min As per Technical Datasheet
Technical Details
Size As per Technical Datasheet
Specification reference IEC 60332-1, IEC60332-3A, IEC 60331, BS
6387 CWZ
Conductor material mm Plain annealed copper wire to IEC
Max operating temperature °C 90
No of Wire / Wire Diameter mm As per Technical Datasheet
Conductor shape Circular stranded
Insulation Cross-linked PE, XLPE
Insulation thickness mm As per Technical Datasheet
Core Colour mm Black & White

Application

  • Most widely used fire resistance speaker & Audio/Motor control cables, which is highly flexible due to the unique tubing design. Draka MAX – FOH flexible speaker cables meets the stringent BS 6387 fire performance standards and can be used in all critical Public Address General Alarm Systems.

Fire Rating

  • Generally to :ISO/IEC 11801:95, IEC 61156, EN 50173:95; EN 50288-1,BS 6387
Ordering Information
P/N Product Description P.U
PAGA2C15 MAX-FOH FlexiTube, 2Cx1.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum
PAGA3C15 MAX-FOH FlexiTube, 3Cx1.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum
PAGA2C25 MAX-FOH FlexiTube, 2Cx2.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum
PAGA3C25 MAX-FOH FlexiTube, 3Cx2.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum