Heavy Armoured Cable Nylon + LSZH Sheath, Chemical/Corrosive Resistant
Features
- Central Strength Member(CSM): glass fiber reinforced plastic rod(FRP), with PE coating when needed.
- Tube: thermoplastic material containing up to 12 optical fibres and filled with a suitable water tightness compound.
- Fire Resistance Layer: mica tape wrapped around loose tube
- Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
- Core Wrapping: water-blocking tape & yarn (dry-core)
- Inner sheath: HDPE
- Nylon sheath: Black Nylon Polyamide 12 (PA 12)
- Outer Armour: Galvanized Steel Wire
- Outer Sheath: LSZH flame retardant
Technical Data | ||||||
---|---|---|---|---|---|---|
No.of Flbres | 4,8,16 | 12,24,36,48,72 | 96 | |||
Design (Elements x Fibre/Tube) | 6×4 | 6 x 12 | 8×12 | |||
Loose Tube/Filler – ø | mm | Nom. 2.3 | Nom. 2.0 | Nom. 2.0 | ||
CSM/sheath diameter | mm | Nom. 3.0 | Nom. 3.0 | Nom. 3.0/4.8 | ||
Outer sheath thickness | mm | Nom. 2.0 | ||||
Cable Diameter | mm | Nom. 17.9 | Nom. 17.9 | Nom. 19.7 | ||
Cable Weight | Kg.Km | 531 | 531 | 624 | ||
Max installation tension | N | 6000 | ||||
Min. bending radius | mm | Without Tension 15 x Cable- ø |
Under Maximum Tension 30 x Cable- ø |
|||
Temperature range | Installation : -10°C->+60°C |
Transport & Storage : -40°C->+70°C |
Transport & Storage: -40°C->+70°C |
Application
The cable is specially designed for harsh environments. The multilayer inner sheath HDPE/PA(nylon) withstands aggressive constituents, fluids that might occur on (petro) chemical plants, aliphatic hydrocarbon resistant. The cable which is low smoke, halogen free and flame-retardant, is suitable for installation under and above ground. – Nylon jacket provides anti-termite protection of the cable
– The steel wire armour provides anti-rodent protection
– The outer sheath is flame retardant compound to Heat & Oil and UV resistant
Flame & Fire Rating
- IEC 60332-3-24 & IEC 60331-25
Main Characteristics | |||
---|---|---|---|
Test | Standard | Specified value | Acceptance Criteria* |
Max. tension at installation (short term) | IEC 60794-1-2-E1 | 5000N | Δ I/I fibre strain ≤ 0.6%, Δα reversible |
Crush | IEC 60794-1-2-E3 | 4000N/100mm | Δα ≤ 0.15dB(SM), 0.3 dB (MM) after test |
Temperature Range | IEC 60794-1-2-F1 | -40 -> + 70ºC | Δα ≤ 0.15dB/km(SM), 0.3 dB /km(MM) |
Water penetration | IEC 60794-1-2-F5C | sample=3m, water=1m | No water leakage after 24 hour |
* Values for single-mode fibres, all optical measurements performed at 1550 nm
* Values for multi-mode fibres, all optical measurements performed at 1300 nm
Ordering Information | ||
---|---|---|
FIRETUF LTFIPNWM SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters LTFIPNWM to denote that it is a FIRETUF LTFIPNWM SERIES FO Cable. This is followed by 3 numbers which symbolizes the core quantity and then 2 letters to denote the fibre type. Example of a FIRETUF LTFIPNWM SERIES FO Cable part number: LTFIPNWM008M1 The above example describes an OM1 (62.5um, Black Sheath) FIRETUF LTFIPNWM SERIES FO Cable, with 8 cores. |
LTFIPNWM SERIES |
Core quantity |
FIBER TYPE |
LTFIPNWM |
XXX |
XX |
---|---|---|
002~096 : (2 CORES ~ 96 CORES) |
SM - SingleMode M1~M4 - MultiMode |