Li-09YS(St)C11Y 2 x 0.35 mm² LSZH

CanBus-Cable

Construction
Conductor Stranded bare copper wire, diameter 7 x 0.26 mm                     
ø 0.78 mm
(cross section 0.35 mm²)
Insulation Foam-Skin PP,
ø 2.2 ± 0.1 mm
wall thickness 0.71 mm
Twisting 2 cores + 2 x PP-fillers twisted to the pair
ø 4.4 mm
Core identification 1x white, 1x green
Overall screen 1 x PET-Al-foil +
ø 4.6 mm
tinned stranded drain wires 19 x 0,15 mm
+ tinned copper braid
ø 5.2 mm
optical coverage ≥ 65%
Foil 1 x PET-foil under sheath
ø 5.3 mm
Sheath PUR Low Smoke Zero Halogen
ø 6.8 ± 0.2 mm
wall thickness 0.75 mm
Sheath colour Black, RAL 9005
Outer Diameter Nom. 6.8 mm
Weight Nom. 46.7 kg/km
Tensile force N 165
Mechanical properties
Bending radius during installation
– without load
– with load
> 5 x cable diameter;

> 10 x cable diameter

Operating temperature – 30°C up to + 70°C
Storage temperature -40°C up to 85°C
UV resistance of sheath material acc. to IEC60068-2-5
Ozone resistance acc. to EN 60811-2-1, clause 8
Smoke density acc. to EN 50268-2, IEC61034-1 and 2
Corrosivity acc. EN 50267-1 and 2, IEC 60754-1 and 2
Electrical properties at 20°C
Conductor resistance (at 20 ± 5 °C) ≥ 54.5Ω /km
Characteristic impedance at 1 MHz 120 Ω± 15%
Insulation resistance (at 20 ± 5 °C and 500 V) >10 GΩxkm
Operating voltage (50 Hz, rms) 60 V
Test voltage (AC, 1 min) Core/core and core/screen 1.2 kV

Application

  • The following CanBus cable is suitable for transmission of CanBus signals according to DIN19245 and EN 50170
  • The following CanBus cable is suitable for transmission of CanBus signals according to ISO 11898 – 2
  • The cable is suited for fixed indoor and outdoor installation and under certain conditions also for mobile use.
  • The cable is halogen free,flame retardant and oil resistant. The sheath material is tested in Hydraulic oil.
  • ARAL VITAM 32, Mobil DTE 13M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320

Flame resistance

  • IEC 60332 – 1,IEC -61034-2,IEC 60754 – 1 /2

Ordering Information
P/N Product Description P.U
1003011 CS2875900 CanBus-Cable, Li-09YS(St)C11Y 2 x 0.35 mm² LSZH 1000m/drum

EIB/KNX – BUS, LSZH

EIB/KNX-Bus Cable

Symmetrical data cable for EIB/KNX-BUS Systems

Application

EIB (European Installation Bus) cable is a special type of BUS cable suitable for use in KNX systems.
EIB/KNX is a shielded bus cable which meets the requirement of “European Installation Bus” standard. It’s widely use in KNX communication for building management for lighting control, heating, air-conditioning, time management, etc.
The cable can be used in dry, wet and damp areas either inside or outside (if protected from direct sunlight)

Fire Rating

  • IEC 60332-1
Construction
Conductor Copper wire, bare 0.5 mm2, ø 0.80 mm
Insulation PE, 1.6 mm ø
Core identification Pair 1: Red, Black, Pair 2: Yellow, White
Pair stranding 2 conductors to the pair
Cable lay up 1 or 2 pairs to the core
Wrapping 1 x PET foil
Overall shielding Laminated AL-foil + Tinned copper drain wire
Outer Sheath LSZH, Green RAL 6018
Mechanical properties
Operating temperature – 25°C up to + 70°C
Min. Installation temperature – 5°C up to + 60°C
Minimum bending radius (without load)  4 x D
Smoke density (only for LSFROH types) acc. to IEC 61034-2
Corrosivity of fire gases (only for LSZH types) acc. to IEC 60754-1/2
Electrical properties at 20°C
Max. Cond. Resistance DC (max.) 37.5 Ω/km
Ordering Information
P/N Product Description P.U
EIB2P0.8L-GN EIB BUS Cable, 2PR x 0.8mm BC Shielded LSZH Green 500m/drum