Draka RS-485 22 AWG FPE

Serial Data Communication Cable

 
Construction
Conductor Stranded Tinned Copper
Insulation Foam PE
Colour Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange
Pair 3: 1 x white, 1 x black Pair 4: 1 x green
1st Screen 1 x AL-Mylar Wrap, overlapping ≥ 25 %
Drain Wire Stranded Tinned Copper
Braid Shield Tinned Copper ; coverage ≥ 85%
Sheath PVC/LSZH/LSZH ATARUV
Braid Armour (Optional) Galvanized Steel Wire Braid
Outer Sheath (Optional) LSZH / LSZH ATARUV
Pair 1P 2P 3P 4P
  Nom. Cable OD mm
TC/FPE/OS/TCWB/PVC 6.5 8.5 9.5 11.5
TC/FPE/OS/TCWB/LSZH 6.5 8.5 9.5 11.5
TC/FPE/OS/TCWB/LSZH ATARUV 6.5 8.5 9.5 11.5
TC/FPE/OS/TCWB/LSZH/SWB/LSZH 10.8 13.4 13.8 15.8
         
 

Application

  • For multi-dropped,medium-speed,serial data communication in electrically noisy industrial environments.Application includes industrial networks using RS-485/RS- 422/RS-232 transceivers, for Process Automation (chemicals, brewing, paper mills), factory automation (autos, metal fabrication), HVAC, security, motor control and motion control.Suitable for outdoor installation.

Flame Rating

  • IEC 60332 – 1
 
Electrical properties  
Conductor Resistance (at 20ºC)   ≤ 58 Ω/km  
Capacitance cond. to cond. Nom. 12.5 pF/ft  
Impedance Nom. 120 Ω  
Rated Voltage 300 V  
Mechanical properties  
Operating temperature -20°C to +70°C  
Bend Radius 10 x OD  
     
Ordering Information
RS-485  part numbers are made up using the table below.
The part number starts with 48 to denote that it is an EIA-485 cable.
The following number shows the number of pairing and the last 2 numbers signifies the AWG.

Example of an EIA-485 part number

48124LB 

The above example describes an RS-485 SWB cable with 1 pair, 24 AWG. Sheath type LSZH, SWB

 

RS- 485 PAIRING AWG SHEATH OUTER JACKET ADDITIVE  
48 X XX X X X  
 
1 - 1 Pair
2 - 2 Pair
4 - 4 Pair


22 -22 AWG

(nil) - PVC
L- LSZH

B - SWB
RTV- Anti-Rodent, Anti-Termite, UV Resistance  
 

Draka RS-485 24 AWG FPE

Serial Data Communication Cable

Construction
Conductor Stranded Tinned Copper
Insulation Foam PE
Colour Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange
Pair 3: 1 x white, 1 x black Pair 4: 1 x green
1st Screen 1 x AL-Mylar Wrap, overlapping ≥ 25 %
Drain Wire Stranded Tinned Copper
Braid Shield Tinned Copper ; coverage ≥ 85%
Sheath PVC/LSZH/LSZH ATARUV
Braid Armour (Optional) Galvanized Steel Wire Braid
Outer Sheath (Optional) LSZH / LSZH ATARUV
Pair 1P 2P 3P 4P
Nom. Cable OD mm
TC/FPE/OS/TCWB/PVC 6.2 8.5 9.1 9.8
TC/FPE/OS/TCWB/LSZH 6.2 8.5 9.1 9.8
TC/FPE/OS/TCWB/LSZH ATARUV 6.2 8.5 9.1 9.8
TC/FPE/OS/TCWB/LSZH/SWB/LSZH 10.7 13.0 13.6 14.3

Application

  • For multi-dropped,medium-speed,serial data communication in electrically noisy industrial environments.Application includes industrial networks using RS-485/RS- 422/RS-232 transceivers, for Process Automation (chemicals, brewing, paper mills), factory automation (autos, metal fabrication), HVAC, security, motor control and motion control.Suitable for outdoor installation.

Flame Rating

  • IEC 60332 – 1
Electrical properties
Conductor Resistance (at 20ºC)   ≤ 89 Ω/km
Capacitance cond. to cond. Nom. 12.5 pF/ft
Impedance Nom. 120 Ω
Rated Voltage 300 V
Mechanical properties
Operating temperature -20°C to +70°C
Bend Radius 10 x OD
Ordering Information
RS-485  part numbers are made up using the table below.
The part number starts with 48 to denote that it is an EIA-485 cable.
The following number shows the number of pairing and the last 2 numbers signifies the AWG.

Example of an EIA-485 part number

48124LB 

The above example describes an RS-485 SWB cable with 1 pair, 24 AWG. Sheath type LSZH, SWB

RS- 485 PAIRING AWG SHEATH OUTER JACKET ADDITIVE
48 X XX X X X
1 - 1 Pair
2 - 2 Pair
4 - 4 Pair


24 -24 AWG

(nil) - PVC
L- LSZH

B - SWB
RTV- Anti-Rodent, Anti-Termite, UV Resistance

Li-2YC11Y 2 x 2 x 0.22 mm² FRNC

CanBus-Cable

Application

  • The following CanBus cable is suitable for transmission of CanBus signals according to DIN19245 and EN 50170
  • The following CanBus cable is suitable for transmission of CanBus signals according to ISO 11898 – 2
  • The cable is suited for fixed indoor and outdoor installation and under certain conditions also for mobile use.
  • The cable is halogen free,flame retardant and oil resistant. The sheath material is tested in Hydraulic oil.
  • ARAL VITAM 32, Mobil DTE 13 M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320

Flame resistance

  • IEC 60332 – 1,IEC -60332-3,IEC 60754 – 1 /2
Construction
Conductor Stranded bare copper wire, diameter 7 x 0.20 mm            
ø 0.60 mm(cross section 0.22 mm²)
Insulation PE,
ø1.75± 0.05 mm
Wall Thickness 0.46mm
Colour code Pair 1: 1 x white, 1 x brown
Core identification Pair 2: 1 x yellow, 1 x green
Cable lay up 4 cores twisted to a star quad
ø 4.2 mm
Wrapping 1 x PET-foil, overlapping
ø 4.3 mm
Overall screen Tinned copper braid
ø 5.0 mm, Optical coverage ≥ 85%
Foil 1 x PET-foil under sheath
ø 5.1 mm
Sheath PUR Low Smoke Zero Halogen
ø 6.9 ± 0.2 mm
Sheath colour Black, RAL 9005
Outer Diameter Nom. 6.9 mm
Weight Nom. 70 kg/km
Tensile force N 165
Mechanical properties
Bending radius
– moving application- fixed application
≥ 10 x outer diameter of cable

≥ 5 x outer diameter of cable

Operating temperature – 40°C up to + 85°C
UV resistance acc. to IEC60068-2-5
Ozone resistance acc. to EN 60811-2-1, clause 8
Smoke density acc. to EN 50268-2, IEC61034-1 and 2
Corrosivity EN 50267-1 and 2, IEC 60754-1 and 2
Electrical properties at 20°C
Conductor resistance (at 20 ± 5 °C) ≥ 87 /km
Characteristic impedance at 1 MHz 120 Ω± 15%
Capacitance at 800 Hz (nominal) 41 nF/kmm
Insulation resistance (at 20 ± 5 °C and 500 V) ≥10 GΩxkm
Capacitance unbalance (pair to ground) 1.2 kV
Ordering Information
P/N Product Description P.U
1003018 CS2878600 CanBus, Li-2YC11Y 2 x 2 x 0.22 mm² FRNC 1000m/drum

Li-09YS(St)C11Y 2 x 0.35 mm² LSZH

CanBus-Cable

Construction
Conductor Stranded bare copper wire, diameter 7 x 0.26 mm                     
ø 0.78 mm
(cross section 0.35 mm²)
Insulation Foam-Skin PP,
ø 2.2 ± 0.1 mm
wall thickness 0.71 mm
Twisting 2 cores + 2 x PP-fillers twisted to the pair
ø 4.4 mm
Core identification 1x white, 1x green
Overall screen 1 x PET-Al-foil +
ø 4.6 mm
tinned stranded drain wires 19 x 0,15 mm
+ tinned copper braid
ø 5.2 mm
optical coverage ≥ 65%
Foil 1 x PET-foil under sheath
ø 5.3 mm
Sheath PUR Low Smoke Zero Halogen
ø 6.8 ± 0.2 mm
wall thickness 0.75 mm
Sheath colour Black, RAL 9005
Outer Diameter Nom. 6.8 mm
Weight Nom. 46.7 kg/km
Tensile force N 165
Mechanical properties
Bending radius during installation
– without load
– with load
> 5 x cable diameter;

> 10 x cable diameter

Operating temperature – 30°C up to + 70°C
Storage temperature -40°C up to 85°C
UV resistance of sheath material acc. to IEC60068-2-5
Ozone resistance acc. to EN 60811-2-1, clause 8
Smoke density acc. to EN 50268-2, IEC61034-1 and 2
Corrosivity acc. EN 50267-1 and 2, IEC 60754-1 and 2
Electrical properties at 20°C
Conductor resistance (at 20 ± 5 °C) ≥ 54.5Ω /km
Characteristic impedance at 1 MHz 120 Ω± 15%
Insulation resistance (at 20 ± 5 °C and 500 V) >10 GΩxkm
Operating voltage (50 Hz, rms) 60 V
Test voltage (AC, 1 min) Core/core and core/screen 1.2 kV

Application

  • The following CanBus cable is suitable for transmission of CanBus signals according to DIN19245 and EN 50170
  • The following CanBus cable is suitable for transmission of CanBus signals according to ISO 11898 – 2
  • The cable is suited for fixed indoor and outdoor installation and under certain conditions also for mobile use.
  • The cable is halogen free,flame retardant and oil resistant. The sheath material is tested in Hydraulic oil.
  • ARAL VITAM 32, Mobil DTE 13M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320

Flame resistance

  • IEC 60332 – 1,IEC -61034-2,IEC 60754 – 1 /2

Ordering Information
P/N Product Description P.U
1003011 CS2875900 CanBus-Cable, Li-09YS(St)C11Y 2 x 0.35 mm² LSZH 1000m/drum

EIB/KNX – BUS, LSZH

EIB/KNX-Bus Cable

Symmetrical data cable for EIB/KNX-BUS Systems

Application

EIB (European Installation Bus) cable is a special type of BUS cable suitable for use in KNX systems.
EIB/KNX is a shielded bus cable which meets the requirement of “European Installation Bus” standard. It’s widely use in KNX communication for building management for lighting control, heating, air-conditioning, time management, etc.
The cable can be used in dry, wet and damp areas either inside or outside (if protected from direct sunlight)

Fire Rating

  • IEC 60332-1
Construction
Conductor Copper wire, bare 0.5 mm2, ø 0.80 mm
Insulation PE, 1.6 mm ø
Core identification Pair 1: Red, Black, Pair 2: Yellow, White
Pair stranding 2 conductors to the pair
Cable lay up 1 or 2 pairs to the core
Wrapping 1 x PET foil
Overall shielding Laminated AL-foil + Tinned copper drain wire
Outer Sheath LSZH, Green RAL 6018
Mechanical properties
Operating temperature – 25°C up to + 70°C
Min. Installation temperature – 5°C up to + 60°C
Minimum bending radius (without load)  4 x D
Smoke density (only for LSFROH types) acc. to IEC 61034-2
Corrosivity of fire gases (only for LSZH types) acc. to IEC 60754-1/2
Electrical properties at 20°C
Max. Cond. Resistance DC (max.) 37.5 Ω/km
Ordering Information
P/N Product Description P.U
EIB2P0.8L-GN EIB BUS Cable, 2PR x 0.8mm BC Shielded LSZH Green 500m/drum