Draka UC500 Cat.6a F/FTP 23AWG LSZH

Standard, Solid, 23AWG, Screened

Application

  • Generic cabling systems
  • Primary (Campus), Secondary (Riser), Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10G Base-T
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM
  • IEEE 802.3af (PoE); IEEE 802.3a(PoE+); IEEE802.3bt (PoE++)

Standards

  • ANSI TIA / EIA 568.2-D
  • ISO/IEC 11801-1/2
  • IEC 61156-5
  • EN 50173-1
  • EN 50288-10-1

Flame Rating

  • LSZH: IEC 60332-1-2 ; IEC 60332-3-22; IEC 60754-1&2; IEC 61034-2
Construction
Conductor Bare copper wire Nom. ≥ ∅ 0.546 mm (AWG23)
Insulation Foam skin PE
Sheath LSZH
Sheath colour BLUE or WHITE
Pair Screen High Performance Individual Pair Screen
Overall Screen Aluminum Laminated Foil, Tinned Copper drain wire (AWG26)
Outer Diameter Nom. 7.5 mm
Weight Nom. 52 kg /km
Mechanical properties
Minimum bending radius without load ≥ 4 x O.D
Minimum bending radius with load ≥ 8 x O.D
Temperature range during operation  -20°C to +60°C
Temperature range during installation  0°C to +50°C
Electrical properties at 20°C
DC Resistance ≤ 9.38 Ω / 100m 
DC Loop Resistance ≤ 187.6 Ω /km
DC Resistance unbalance ≤4 %
Mutual Capacitance at 1 kHz ≤ 5.6 nF /100m
Capacitance unbalance (pair to ground) ≤ 330 pF /100m
Characteristic impedance 1- 100 MHz 100 ± 15 Ω
Nominal velocity of propagation Nom. 75 %
Propagation delay (@250MHz) ≤  536 ns /100m
Delay skew ≤ 45 ns /100m
Ordering Information
SAP IC UC P/N Product Description P.U
60094736  84075WH-5H Draka UCDATA CATEGORY CABLE UC500 CAT.6A FFTP 4PAIR 23AWG LSZH WHITE IEC60332-1 500m/reel

Draka UC300 Cat.5e U/UTP 24AWG

Standard, Solid

 
Construction
Conductor Bare copper wire Nom. ≥ ø 0.482 mm (AWG24)
Insulation PE
Sheath PVC & LSZH ( Ripcord underneath)
Sheath colour Grey
Outer Diameter Nom. ∅ 5.0 mm
Weight Nom. 28.0 kg / km
Mechanical properties
Minimum bending radius with load ≥ 8 X OD
Minimum bending radius without load ≥ 4 X OD
Maximum tensile load, Installation Nom. 100N
Temperature range during operation -20°C up to +60°C
Temperature range during installation  0°C up to +50°C
Electrical properties at 20°C
Characteristic Impedance (1-100 MHz)  100 ± 15 Ω
DC Loop Resistance ≤187.6 Ω /km
DC Resistance Unbalance   ≤ 5%
Mutual Capacitance (@800 Hz)   ≤ 5.6 nF/100m
Capacitance Unbalance (pair to ground)   ≤  330 pF/100m
Velocity of Propagation Nom. 65%
Propagation Delay (@100 MHz) ≤ 536.0 ns/100m
Delay Skew ≤ 45.0 ns/100m
Max Attenuation @100 MHz 22.0 dB/100m
Min. NEXT @100MHz 35.3 dB/100m
Min. PS-NEXT @100MHz 32.3 dB/100m
Min. ELFEXT @100 MHz 23.8 dB/100m
Min. PS-ELFEXT @100 MHz 20.8 dB/100m
Min. Return Loss @ 100 MHz 20.1 dB/100m
   
  • * All above stated values are nominal and subject to changes.
  • * More details on electrical properties available at technical datasheet.

Application

    • Primary (Campus)
    • Secondary (Riser)
    • Tertiary (Horizontal)
    • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;
    • IEEE 802.5 16 MB; ISDN; TPDDI; ATM
    • Power over Ethernet PoE/PoE+
    • IEEE 802.3af and IEEE 802.3at

Standards

  • ANSI TIA/EIA 568-C.2;
  • ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd ed.;
  • EN 50173; EN 50288-3-1

Flame Rating

  • PVC IEC 60332-1-2
  • LSZH IEC 60332-1-2; IEC 60754-1&2; IEC 61034-2
 
Ordering Information  
SAP IC UC P/N Product Description P.U  
60093910 52004GY-3H Draka UCDATA CATEGORY CABLE UC300 CAT.5E  UUTP 4 PAIR 24AWG PVC GREY IEC60332-1, Indoor 305m/box  
60093912 52026GY-3H Draka UCDATA CATEGORY CABLE UC300 CAT.5E  UUTP 4 PAIR 24AWG LSZH GREY IEC60332-1, Indoor 305m/box  

 

Draka UC500 Cat.6a U/UTP UNSHIELDED 23AWG LSZH

Premium, Solid, 23AWG, UUTP Unshielded

Application

  • Generic cabling systems
  • Primary (Campus), Secondary (Riser), Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10G Base-T
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM
  • IEEE 802.3af (PoE); IEEE 802.3a(PoE+); IEEE802.3bt (PoE++)

Standards

  • ANSI TIA / EIA 568.2-D
  • ISO/IEC 11801-1/2
  • IEC 61156-5
  • EN 50173-1
  • EN 50288-10-1

Flame Rating

  • LSZH: IEC 60332-1-2; IEC 60332-3-22; IEC 60754-1&2; IEC 61034-2
Construction
Conductor Bare copper wire ∅ 0.56 mm (AWG23)
Insulation PE/Foam PE , Nom. ∅ 1.15 mm
Sheath LSZH
Sheath colour BLUE
Overall Screen PE Mylar and Single PET AL-Foil (without Drain Wire)
Outer Diameter Nom. 7.1 mm
Weight Nom. 56 kg /km
Mechanical properties
Minimum bending radius without load ≥ 8 x O.D
Minimum bending radius with load ≥ 8 x O.D
Temperature range during Operation  -20°C to +60°C
Temperature range during Installation  0°C to +50°C
Maximum Pulling Force during Installation  110N
Electrical properties at 20°C
DC Resistance ≤ 9.38 Ω / 100m 
DC Loop Resistance ≤ 187.6 Ω /km
DC Resistance unbalance ≤ 4 %
Mutual Capacitance at 1 kHz 5.6 nF /100m
Capacitance unbalance (pair to ground) ≤ 330 pF /100m
Characteristic impedance 1- 100 MHz 100 ± 15 Ω
Nominal velocity of propagation Nom. 75 %
Propagation delay (@250MHz) ≤  536 ns /100m
Delay skew ≤ 45 ns /100m
Ordering Information
SAP IC UC P/N Product Description P.U
TBC  80345BL-5H Draka UCDATA CATEGORY CABLE UC500 CAT.6A UUTP UNSHIELDED 4PAIR 23AWG LSZH BLUE 500m/reel

Draka UC500 Cat.6a F/FTP 23AWG LSFRZH-3A

Premium, Solid, 23AWG, Screened

Application

  • Generic cabling systems
  • Primary (Campus), Secondary (Riser), Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10G Base-T
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM
  • IEEE 802.3af (PoE); IEEE 802.3a(PoE+); IEEE802.3bt (PoE++)

Standards

  • ANSI TIA / EIA 568.2-D
  • ISO/IEC 11801-1/2
  • IEC 61156-5
  • EN 50173-1
  • EN 50288-10-1

Flame Rating

  • LSZH: IEC 60332-1-2; IEC 60332-3-22; IEC 60754-1&2; IEC 61034-2
Construction
Conductor Bare copper wire ∅ 0.55 mm (AWG23)
Insulation Foam skin PE , Nom. ∅ 1.25 mm
Sheath LSZH
Sheath colour BLUE
Pair Screen High Performance Individual Pair Screen
Overall Screen Aluminum Laminated Foil, Tinned Copper drain wire (AWG26)
Outer Diameter Nom. 7.5 mm
Weight Nom. 52 kg /km
Mechanical properties
Minimum bending radius without load ≥ 4 x O.D
Minimum bending radius with load ≥ 8 x O.D
Temperature range during operation  -20°C to +60°C
Temperature range during installation  0°C to +50°C
Electrical properties at 20°C
DC Resistance ≤ 9.38 Ω / 100m 
DC Loop Resistance ≤ 187.6 Ω /km
DC Resistance unbalance ≤4 %
Mutual Capacitance at 1 kHz 5.6 nF /100m
Capacitance unbalance (pair to ground) ≤ 330 pF /100m
Characteristic impedance 1- 100 MHz 100 ± 15 Ω
Nominal velocity of propagation Nom. 75 %
Propagation delay (@250MHz) ≤  536 ns /100m
Delay skew ≤ 45 ns /100m
Ordering Information
SAP IC UC P/N Product Description P.U
TBC  84045BL-5H Draka UCDATA CATEGORY CABLE UC500 CAT.6A FFTP 4PAIR 23AWG LSFRZH-3A BLUE 500m/reel

UC1500 HS22 Cat.7A S/FTP

Standard, Solid, LSZH

Construction
Conductor Bare copper wire, Nom. ø 0.62 mm (AWG22/1)
Insulation Foam-Skin Polyethylene
Twisting 2 cores to the pair
Pair Screen Al-laminated plastic foil around each pair
Cable Lay Up 4 Pairs
Screen Tinned Copper Braid
Sheath LSZH
Outer Diameter Nom 7.6mm
Weight Nom 63.7 kg/km
Mechanical properties
Bending radius without load ≥8 X OD
with load ≥ 4 X OD
Temperature range during operation -20°C to + 60°C
during installation 0°C to + 50°C
Electrical properties at 20°C ± 5°C
Loop resistance 128 Ω/km
Insulation resistance (500 V) 5000 MΩ.km
Mutual capacitance at 800 Hz Nom. 43 pF/m
Characteristic impedance @ 100 MHz Nom. 100Ω
Nominal velocity of propagation 79 %
Propagation delay 427 ns/100m
Delay skew 12 ns/100m
Transfer impedance At 10 MHz  10mΩ/m
Coupling attenuation  80 dB
Attenuation @ 1500 Mhz 64.3 dB
NEXT @ 1500 Mhz 80.0 dB
PS-NEXT @ 1500 Mhz 77.0 dB
ACR @ 1500 Mhz 16.0 dB
PS-ACR @ 1500 Mhz 13.0 dB
PS-ACR-F @ 1500 Mhz 25.0 dB

Application

  • Primary (Campus)
  • Secondary (Riser)
  • Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;10GBase-T
  • 1000Base-T, 10GBase-T; IEEE 802.5, ISDN, TPDDI, ATM, CATV,Broadband Video
  • Power over Ethernet (PoE) / PoE+
  • IEEE 802.3af and IEEE 802.3at

Standards

  • ISO / IEC 11801 2nd Ed
  • IEC 61156 2nd Ed
  • EN 50173; EN 50288-9-1

Fire Rating

  • LSZH IEC 60332-1
Ordering Information
SAP IC Product Description P.U
60088553 UC 1500 HS22 Cat.7A S/FTP, Individual pair foil, Copper Braid, LSZH 500m/reel

Draka UC900 Cat.7 S/FTP 23AWG LSZH

Standard, Solid, 23AWG, Screened

Construction
Conductor Bare copper wire, Nom. ∅ 0.56 mm (AWG 23)
Insulation Foamskin PE
Twisting 2 cores to the pair
Pair Screen Al-laminated plastic foil
Cable Lay Up 4 pairs (PiMF) to the core
Screen Copper braid, tinned
Sheath LSZH Blue
Outer Diameter Nom. 7.5mm
Weight Nom. 52 kg/km
Mechanical properties
Bending radius without load ≥ 8 X OD
with load ≥ 4 X OD
Temperature range during operation -20°C to + 60°C
during installation 0°C to + 50°C
Electrical properties at 20°C ± 5°C
DC Loop resistance ≤ 149.4Ω/km
Resistance unbalance ≤ 2%
Insulation resistance (500 V) ≥ 5000 MΩ/km
Capacitance Unbalance (Pair/Ground) ≤ 1500 pF/km
Characteristic impedance (1-100 MHz)  100 ± 5 Ω
(100 – 250) MHz  100 ± 10 Ω
(250 – 600) MHz  100 ± 15 Ω
Delay skew ≤ 25 ns/100m
Test voltage (DC, 1 min) core/core and
core/screen
1000 V
Coupling attenuation ≥ 80 dB
Max. Attenuation @ 600 Mhz 50.1 dB
Max. NEXT @ 600 Mhz 60.7 dB
Max. ACR-F @ 600 Mhz 38.4 dB
Max. Return Loss @ 600 Mhz 17.3 dB
Max. TCL @ 600 Mhz 12.2 dB

Application

  • Primary (Campus)
  • Secondary (Riser)
  • Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;10GBase-T
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM

Standards

  • IEC 61156-1 & 5
  • EN 50288-4-1

Flame Resistance

  • LSZH IEC 60332-1
Ordering Information
SAP IC UC P/N Product Description P.U
60101091 73075BL-5H Draka UCDATA CATEGORY CABLE UC900 CAT.7 SFTP 4 PAIR 23AWG BLUE IEC 60332-1, IEC60754-1&2, IEC61034 500m/reel

DRAKA UC400 CAT.6 S/FTP 23AWG

Standard, Solid, 23AWG, Screened

Construction
Conductor Solid copper wire Nom. ≥ Ø 0.546 (23AWG)
Insulation PE
Pair Screen High Performance Individual Pair Screen
Overall Screen Tinned Copper Wire Braiding
Sheath LSZH
Sheath colour BLUE
Outer Diameter Nom. Ø 7.5 mm
Weight Nom. 52.0 kg/km
Mechanical properties
Minimum bending radius with load ≥ 8 X OD
Minimum bending radius without load ≥ 4 X OD
Temperature range during operation -20°C up to +60°C
Temperature range during installation 0°C up to +60°C
Electrical properties at 20°C
Characteristic Impedance (1-100 MHz) 100 ± 15 Ω
DC Loop Resistance ≤ 187.6 Ω/km
DC Resistance Unbalance ≤ 2.5%
Mutual Capacitance (@800 Hz) ≤ 5.6 nF/100m
Capacitance Unbalance (pair to ground) ≤ 550 pF/100m
Velocity of Propagation Nom. 74%
Propagation Delay (@250 MHz) ≤ 570.0 ns/100m
Delay Skew ≤ 45.0 ns/100m
Max Attenuation @250 MHz ≤ 32.8 dB/100m
Min. NEXT @250 MHz ≥ 38.3 dB/100m
Min. PS-NEXT @250 MHz ≥ 36.3 dB/100m
Min. ELFEXT @250 MHz ≥ 19.8 dB/100m
Min. PS-ELFEXT @250 MHz ≥ 16.8 dB/100m
Min. Return Loss @250 MHz ≥ 17.3 dB/100m
  • * All above stated values are nominal and subject to changes
  • * For more details on electrical properties please request for datasheet.
Ordering Information
SAP IC UC P/N Product Description P.U
60099901  65075BL-5H Draka UCDATA CATEGORY CABLE UC400 CAT.6 SFTP 4PAIR 23AWG LSZH BLUE 500m/reel

Application

  • Primary (Campus)
  • Secondary (Riser)
  • Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM
  • Power over Ethernet PoE/PoE+
  • IEEE 802.3af and IEEE802.3at

Standards

  • EIA/TIA 568C;
  • ISO/IEC 11801 2nd ed.; IEC 61156-5
  • EN 50173; EN 50288-3-1

Flame Rating

  • LSZH IEC 60332-1-2; IEC 60754-1&2; IEC 61034-2