Security & Comms Cable, SACU Series

Unshielded, PVC CMR, PE, LSZH

Application

  • Security, Intercom, Broadcast, Sound, Audio Systems

Flame rating

  • PVC NEC Article Type FPLR, CL3R, CMR, comply to IEC 60332-1
  • LSZH IEC 60332-1
Construction
Conductor Grade A Bare Copper, Stranded
Operating Voltage 300V
Insulation PVC
Insulation colour 1 – Black, 2 – Red, 3 – White, 4 – Green
Ripcord Available
Sheath colour PVC-CMR or LSZH Grey; PE Black
Rated temperature Up to 75°C
Cable Dimension
Conductor Size No of Pairs OD (mm)
12 AWG 1 Pair 7.5
2 Pairs 11.2
14 AWG 1 Pair 6.5
2 Pairs 9.6
16 AWG 1 Pair 5.1
2 Pairs 7.5
18 AWG 1 Pair 4.5
2 Pairs 6.5
20 AWG 1 Pair 4.1
2 Pairs 6.0
22 AWG 1 Pair 3.7
2 Pairs 5.2
Ordering Information
SACU Series part numbers are made up using the table below.

The part number starts with SACU to denote that it is a SACU cable.
The following number shows the number of pairs and the last 2 numbers signifies the AWG.
Any letter behind would describe the sheath type and jacket colour.

Example of a SACU part number-SACU1P16CGY 

The above example describes SACU cable with 2 pairs, 16 AWG. Sheath type PVC CMR with Grey jacket

SACU PAIRING AWG SHEATH  Colour
SACU X XX X X
1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
20 – 20 AWG
22 – 22 AWG
(nil) – PVC-CMR
E – PE
L- LSZH
GY-Grey

UCCONNECT® UC9500 High Density Fibre Suite

UC9500 MTP®/MPO Module

Features

  • Recommended for method/polarity “B“ 10G MPO
    channel using Type “B“ MPO Trunk Cable to achieve
    simple migration to method/polarity “B“ 40/100G
    MPO channel
  • Available in Duplex LC
  • Utilizes bend-insensitive fibre
  • Available in G657A, OM3 and OM4
  • Plug & Play Installation
  • Type“P”is Draka UC defacto, Type A and B are available

Application

UC9500 Module MPO/MTP® LC-Duplex is designed specifically to fit UC9500 Distribution Panel. Design and engineered to reduce total cost of ownership when deployed with 12-Fibre MPO-MPO, or 12-Fibre MTP-MTP, fibre trunks. This module supports the popular 2-fibre 10Gb up to the next generation 25Gb/40Gb/100Gb/400Gb applications. MTP® is a registered 12-fibre MPO connector, trademark of USCONEC.

Contruction
Module Housing Material Aluminum Alloy, Thickness 0.8mm
Module Housing Surface Finish Watermark painted
Module Housing Colour Black
LC-Duplex Adaptor Colour OM3 : AQUA ; OM4 : VIOLET ; Singlemode : BLUE
Environmental
Operating Temperature -20°C to + 70°C
Storage and shipping temperature -40°C to + 75°C


Ordering Information
UC P/N Product Description P.U
PPMSPM19541D-P12 Draka UCCONNECT UC9500 SERIES 1x MPO/APC-12(M)-LC/UPC(D) MODULE SM G.657A2 TYPE P BLUE 1 set/ box
PPMLPM19541D-P12 Draka UCCONNECT UC9500 SERIES LOW LOSS 1x MPO/APC-12(M)-LC/UPC(D) MODULE SM G.657A2 TYPE P BLUE 1 set/ box
PPMSPM29542D-P24 Draka UCCONNECT UC9500 SERIES LOW LOSS 2x MPO/APC-12(M)-LC/UPC(D) MODULE SM G.657A2 TYPE P BLUE 1 set/ box
* For more information, please download technical datasheet.

UCCONNECT® UC9500 High Density Fibre Suite

UC9500 Splice Tray Cover

Features

  • Light weight for easy handling
  • High quality fingerprint and dust resistant surfaces
  • It is compatible with stackable UC9500 Splice Tray; its detachable to fit onto top of a splice tray stack.

Application

UC9500 Splice Tray Cover keeps the fusion splices away from accidental stress-strain, water droplets and dust particles.

Colour : Black

Technical Information
Material Details
Cover material ABS

UC9500 Splice Tray Cover

UC9500 24-Fibre Splice Tray (Cover-less)

Features

  • Stackable with detachable cover
  • Light weight
  • Highly durable
  • Support up to 24multimode and single-mode fusion splice.

Application

UC9500 24-Fibre Splice Tray is a fusion splice enclosure, providing critical protection for fusion splices and is compatible with UC9500 1U Distribution Panel-Slot Empty Fixed.

Technical Information
Material Details
Cover material ABS
Colour Black
Weight
Surface finish Resistant to finger-print and dust

UC9500 24-Fibre Splice Tray (Cover-less)

Ordering Information
UC P/N Product Description P.U
PPST9521-C Draka UCCONNECT Fibre Splice Tray Cover for PPST9521-24 Black 1pc
PPST9521-24 Draka UCCONNECT Fibre Splice Tray 12-24 Fibre for UC9500 Series Black 2pc/box
PPST95-48 Draka UCCONNECT Fibre Splice Tray 48 Fiber For UC9500 Series White 1pc

UCCONNECT® UC9500 High Density Fibre Suite

UC9500 Front-Panel

Features

  • Left and right push-pull rivet
  • Support Single-Mode & Multi-Mode Simplex/Duplex/Quadruplex adaptor.
  • Support LC, SC, FC, MPO, ST.
  • Light Weight
  • Easy and fast adds, moves and changes.
  • Easy Handling

Application

Front Plate for UC9500 Series.

Construction
Material Details
Plate material SPCC Steel (Cold Rolled Steel Plate)

Ordering Information
Please contact our local offices for more details or refer to technical datasheet available below.

UCCONNECT® UC9500 Series Distribution Panel

UC9500 Distribution Panel, Empty

Features

  • Supported adaptor includes LC. SC , FC, ST, MPO , MTP®
  • Mount to standard EIA 19″ rack rails
  • Removable top cover provides access to connections, fibres, and slack storage in rear of tray
  • Multiple trunk cable entry locations provided on rear and sides of enclosure
  • Include fiber optic cable routing kit for cable management

Application

UC9500 Distribution Panel use to house and organize the trunk fiber optic cable, compatible with MPO-LC cassettes, fiber adaptor panels and patch cords. Easy access from front and rear. It is ideal for fast and reliable patch solutions within main, horizontal and equipment distribution areas.

Construction
Material Details
Matrix SPCC (Cold rolled Steel Plate)
Surface Finishing Powder Coating
Dimension 1U x 482 mm x 300 mm; 2U x 482 mm x 300 mm, 4U x 482 mm x 452 mm
Weight 3.26kg (1U), 6kg (2U/4U)

* Standard Panel comes without fibre adaptor, front-panel and splice tray.

* Fits up to 2x UC9500 Splice Tray 24F (PPST9521-24) and 1x UC9500 Splice Tray Cover (PPST9521-C) per each rack unit.


Ordering Information
UC P/N Product Description P.U
PP9510 Draka UCCONNECT FIBRE OPTIC PATCH PANEL FLAT TYPE 19″ 1U 4 SLOT EMPTY BLACK UC9500 Series 1pc
PP9515 Draka UCCONNECT FIBRE OPTIC PATCH PANEL DRAWER TYPE 19″ 1U 4 SLOT EMPTY BLACK UC9500 Series 1pc
PP9520 Draka UCCONNECT FIBRE OPTIC PATCH PANEL FLAT TYPE 19″ 2U 8 SLOT EMPTY BLACK UC9500 Series 1pc
PP9540 Draka UCCONNECT FIBRE OPTIC PATCH PANEL FLAT TYPE 19″ 4U 12 SLOT EMPTY BLACK UC9500 Series 1pc

MPO/MTP® Hydra Cable Assemblies

Indoor, LSZH, Low Loss, MTP® or MPO

Overview

  • Material of cable sheath is Low Smoke Halogen Free
  • Fibre Type: Please refer to technical datasheet
Technical Specification
Item Technical Parameters
Connector Type MPO/MTP® LC/SC
Max. Insertion Loss 0.50dB (MM)

0.75dB (SM)

0.25dB (MM)

0.30dB (SM)

Min. Return Loss 26dB (MM)

45dB (SM – UPC)

55dB (SM – APC)

30dB (MM)50dB (SM – UPC)

65dB (SM – APC)

Note: The insertion loose based on above value need to plus fiber attenuation.

  • MTP® is a registered MPO connector, Trademark of USCONEC
  • Low loss fibres or Draka BendBright™ fibres are used for better insertion
    loss requirements when needed.
  • Factory Terminated and Component Tested
Ordering Information
Please contact our local offices for more details or refer to technical datasheet available below

MTP®/MPO Pre-Terminated Trunk Cable

Indoor, LSZH, Low Loss, MTP® or MPO

  • MTP® is a registered MPO connector, Trademark of USCONEC
  • Low loss fibres or Draka BendBright™ fibres are used for better insertion
    loss requirements when needed.
  • Factory Terminated and Component Tested

Overview

  • Female (Standard) & Male MTP Connectors.
  • Type A , B and C available.
  • Factory Terminated and Tested.
  • Lightweight & High density
  • Sheath : Flame Retardant LSZH
Technical Specification
Item Technical Parameters
Connector Type Max. Insertion Loss Min. Return Loss
 MPO/ MTP ™ MM : 0.50dB ; 0.35dB (Low Loss)

SM : 0.75d ; 0.35dB (Low Loss)

MM : 26 dB

SM : 45 dB (UPC) ; 55dB (APC)

Note: The insertion loose based on above value need to plus fiber attenuation.

Ordering Information
Please contact our local offices for more details or refer to technical datasheet available below.

UC1500 HS22 Cat.7A S/FTP

Standard, Solid, LSZH

Construction
Conductor Bare copper wire, Nom. ø 0.62 mm (AWG22/1)
Insulation Foam-Skin Polyethylene
Twisting 2 cores to the pair
Pair Screen Al-laminated plastic foil around each pair
Cable Lay Up 4 Pairs
Screen Tinned Copper Braid
Sheath LSZH
Outer Diameter Nom 7.6mm
Weight Nom 63.7 kg/km
Mechanical properties
Bending radius without load ≥8 X OD
with load ≥ 4 X OD
Temperature range during operation -20°C to + 60°C
during installation 0°C to + 50°C
Electrical properties at 20°C ± 5°C
Loop resistance 128 Ω/km
Insulation resistance (500 V) 5000 MΩ.km
Mutual capacitance at 800 Hz Nom. 43 pF/m
Characteristic impedance @ 100 MHz Nom. 100Ω
Nominal velocity of propagation 79 %
Propagation delay 427 ns/100m
Delay skew 12 ns/100m
Transfer impedance At 10 MHz  10mΩ/m
Coupling attenuation  80 dB
Attenuation @ 1500 Mhz 64.3 dB
NEXT @ 1500 Mhz 80.0 dB
PS-NEXT @ 1500 Mhz 77.0 dB
ACR @ 1500 Mhz 16.0 dB
PS-ACR @ 1500 Mhz 13.0 dB
PS-ACR-F @ 1500 Mhz 25.0 dB

Application

  • Primary (Campus)
  • Secondary (Riser)
  • Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;10GBase-T
  • 1000Base-T, 10GBase-T; IEEE 802.5, ISDN, TPDDI, ATM, CATV,Broadband Video
  • Power over Ethernet (PoE) / PoE+
  • IEEE 802.3af and IEEE 802.3at

Standards

  • ISO / IEC 11801 2nd Ed
  • IEC 61156 2nd Ed
  • EN 50173; EN 50288-9-1

Fire Rating

  • LSZH IEC 60332-1
Ordering Information
SAP IC Product Description P.U
60088553 UC 1500 HS22 Cat.7A S/FTP, Individual pair foil, Copper Braid, LSZH 500m/reel

Draka UC900 Cat.7 S/FTP 23AWG LSZH

Standard, Solid, 23AWG, Screened

Construction
Conductor Bare copper wire, Nom. ∅ 0.56 mm (AWG 23)
Insulation Foamskin PE
Twisting 2 cores to the pair
Pair Screen Al-laminated plastic foil
Cable Lay Up 4 pairs (PiMF) to the core
Screen Copper braid, tinned
Sheath LSZH Blue
Outer Diameter Nom. 7.5mm
Weight Nom. 52 kg/km
Mechanical properties
Bending radius without load ≥ 8 X OD
with load ≥ 4 X OD
Temperature range during operation -20°C to + 60°C
during installation 0°C to + 50°C
Electrical properties at 20°C ± 5°C
DC Loop resistance ≤ 149.4Ω/km
Resistance unbalance ≤ 2%
Insulation resistance (500 V) ≥ 5000 MΩ/km
Capacitance Unbalance (Pair/Ground) ≤ 1500 pF/km
Characteristic impedance (1-100 MHz)  100 ± 5 Ω
(100 – 250) MHz  100 ± 10 Ω
(250 – 600) MHz  100 ± 15 Ω
Delay skew ≤ 25 ns/100m
Test voltage (DC, 1 min) core/core and
core/screen
1000 V
Coupling attenuation ≥ 80 dB
Max. Attenuation @ 600 Mhz 50.1 dB
Max. NEXT @ 600 Mhz 60.7 dB
Max. ACR-F @ 600 Mhz 38.4 dB
Max. Return Loss @ 600 Mhz 17.3 dB
Max. TCL @ 600 Mhz 12.2 dB

Application

  • Primary (Campus)
  • Secondary (Riser)
  • Tertiary (Horizontal)
  • IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;10GBase-T
  • IEEE 802.5 16 MB; ISDN; TPDDI; ATM

Standards

  • IEC 61156-1 & 5
  • EN 50288-4-1

Flame Resistance

  • LSZH IEC 60332-1
Ordering Information
SAP IC UC P/N Product Description P.U
60101091 73075BL-5H Draka UCDATA CATEGORY CABLE UC900 CAT.7 SFTP 4 PAIR 23AWG BLUE IEC 60332-1, IEC60754-1&2, IEC61034 500m/reel