ICS IE ToughCat 7S* Armoured

S/FTP Installation Cable for tougher environments

Construction
Conductor Solid copper wire, ø 0.56 mm (AWG 23)
Insulation foamskin PE
Twisting 2 cores to the pair
Pair screen Al-laminated plastic foil
Cable lay up 4 pairs (PiMF) to the core
Screen Tinned Copper Braid
Inner Sheath Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1)
Outer sheath Grey RAL7035
Armouring Galvanized steel wire braid, Wire diameter 0,25mm
Outer sheath Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1)
Outer Diameter Nom. 10.6 mm
Weight Nom. 168 kg/km
Mechanical properties
Bending radius Installation 8 x D
Installed 4 x D
Temperature range During operation -40°C to + 85°C
During installation -15°C to + 50°C
Fire load 4 pair 1540 MJ/km
Maximum tensile load During operation No load
During installation 200 N
Electrical properties at 20°C ± 5°C
Loop resistance ≤ 150 Ω/km
Resistance unbalance ≤ 2%
Mutual Capacitance at 800 Hz Nom. 43 nF/km
Capacitance unbalance (pair/ground) ≤ 1500 pF/km
Characteristic impedance (1-100 MHz) 100 Ω± 5 Ω
(100 – 250) MHz 100 Ω± 10 Ω
(250 – 600) MHz 100 Ω± 15 Ω
Nominal velocity of propagation ca. 79 %

Application

  • Generic Data transmission. This cable is a Cat7 S/FTP cable is meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. The Steel Wire Braid offers extra robustness rodent protection.

Standards

  • EN50173-1, EN50288-4-1
  • ISO/IEC 11801, IEC61156-5
  • Det Norske Veritas(DNV) specification No. 6-827.50-2

Flame Rating

  • IEC 60332 – 1 & IEC 60332-3-24

Chemical Resistance

  • Mineral oils IRM902(IEC 60811-2-1)
  • Diesel – IRM 903(IEC60811-2-1)

Certification

  • This cable is based on the unarmoured version certified by: Det Norske Veritas(DNV)
Electrical Transmission Characteristics at 20°C
F Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss
(MHZ) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB/100m)
1 1.8 100 97 98 95 105 105
4 3.4 100 97 97 94 105 102 27
10 5.4 100 97 95 92 97 94 30
16 6.8 100 97 93 90 93 90 30
20 7.7 100 97 92 89 91 88 30
31.25 9.6 100 97 92 89 91 88 30
62.50 13.7 100 97 86 83 81 78 30
100 17.4 100 97 83 80 77 74 30
125 19.5 95 92 75 72 75 72 26
155.5 21.9 94 91 72 69 73 70 26
175 23.3 93 90 70 67 72 69 25
200 25.0 92 89 67 64 71 68 25
250 28.1 90 87 62 59 69 66 24
300 30.9 89 86 58 55 67 64 24
600 44.8 85 82 40 37 61 58 22
Ordering Information
P/N Product Description P.U
60027371 ToughCat7S_SWB SFTP 4×2/0.56 500DP 500m/drum

ICS IE ToughCat 7 LSHF-FR MUD

S/FTP Installation Cable 4x2xAWG23/7 for tougher environments

Application

  • Generic Data transmission. This Cat7 S/FTP cable is based on our DNV and Llyod Register certified ToughCat,but with an additional flame retardant, halogen-free, low smoke MUD protecting outer jacket. This cable is meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units

Standards

  • EN50173-1, EN50288-4-1
  • ISO/IEC 11801, IEC61156-5
  • Det Norske Veritas(DNV) specification No. 6-827.50-2

Flame Rating

  • MUD protecting outer sheath: IEC60754-1, IEC 61034, IEC 60332-3-24
  • Inner Sheath: IEC60754-1, IEC 61034, IEC 60332-3-24

Chemical Resistance

  • Mineral oils IRM902(IEC 60811-2-1)
  • Diesel – IRM 903(IEC60811-2-1)
Construction
Conductor Stranded copper wire, cross section ∅ 0.27 mm² (AWG23/7)
Insulation PE
Twisting 2 cores to the pair
Cable lay up 4 pairs
Pair screen Al-laminated plastic foil around each pair
Overall screen Tinned Copper Braid
Inner Sheath Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1)
Colour Grey RAL 7035
Outer sheath MUD protecting
Colour Grey RAL 7024
Outer Diameter Nom. 10.1 mm
Weight Nom. 112 kg/km
Tensile force N 100
Mechanical properties
Bending radius Without load 8 X D
With load 4 x D
Temperature range During operation -40°C to + 85°C
During installation -15°C to + 50°C
Maximum tensile load During operation No load
During installation 100 N
Electrical properties at 20°C± 5°C
DC Loop resistance ≤ 138 Ω/km
Resistance unbalance ≤ 2%
Mean Characteristic impedance @ 100 MHz 100 Ω± 5 Ω
Nominal velocity of propagation 76%
Electrical Transmission Characteristics at 20°C
Freq. Attenuation NEXT ACR Return loss PS-NEXT
(MHZ) (dB/100m) (dB) (dB/100m) (dB) (dB)
1 2.0 90 88 87
4 3.6 90 86 27 87
10 5.5 90 84 30 87
16 7.5 90 82 30 87
20 7.7 90 82 30 87
31.25 9.8 90 80 30 87
62.50 14.0 86 72 30 83
100 17.9 83 65 30 80
155 22.4 81 59 26 78
200 25.6 78 52 25 75
250 28.8 77 48 25 75
300 31.6 73 41 23 70
600 45.7 71 25 20 68
Ordering Information
P/N Product Description P.U
60015695 ToughCat MUD C7 S/FTP 4Px0.27mm² 500m/drum

ICS IE ToughCat 7 LSHF-FR

S/FTP Installation Cable 4x2xAWG23/7 for tougher environments

Construction
Conductor Stranded copper wire, cross section 0.27 mm² (AWG23/7)
Insulation PE
Twisting 2 cores to the pair
Cable lay up 4 pairs
Pair screen Al-laminated plastic foil around each pair
Overall screen Tinned Copper Braid
Sheath Oil resistant, Fire retardant and halogen free LSZH-FR (SHF1), diameter 8.1 mm
Colour Grey RAL 7035
Outer Diameter Nom. 8.1 mm
Weight Nom. 75 kg/km
Tensile force N 100
Mechanical properties
Bending radius Without load 8 x D
With load 4 x D
Temperature range During operation -40°C to + 85°C
During installation -15°C to + 50°C
Fire load 4 pair 670 MJ/km
Maximum tensile load During operation No load
During installation 140 N
Electrical properties at 20°C
DC Loop resistance ≤ 138 Ω/km
Resistance unbalance ≤ 2%
Mean Characteristic impedance @ 100 MHz 100 Ω± 5 Ω
Nominal velocity of propagation 76%

Application

  • Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units.

Standards

  • EN50173-1,EN50288-4-1
  • ISO/IEC 11801,IEC61156-5
  • Det Norske Veritas(DNV) specification No. 6-827.50-2

Flame Rating

  • IEC 60332 – 1 , IEC 60332-3-24, IEC -61034-2, IEC 60754 – 1 /2

Chemical Resistance

  • Mineral oils IRM902(IEC 60811-2-1)
  • Diesel – IRM 903(IEC60811-2-1)

Certification

  • This cable is certified by :Det Norske Veritas(DNV) and American Bureau of Shipping(ABS)
Electrical Transmission Characteristics at 20°C
Freq. Attenuation NEXT ACR Return loss PS-NEXT
(MHZ) (dB/100m) (dB) (dB/100m) (dB) (dB)
1 2.0 90 88 87
4 3.6 90 86 27 87
10 5.5 90 84 30 87
16 7.5 90 82 30 87
20 7.7 90 82 30 87
31.25 9.8 90 80 30 87
62.50 14.0 86 72 30 83
100 17.9 83 65 30 80
155 22.4 81 59 26 78
200 25.6 78 52 25 75
250 28.8 77 48 25 74
300 31.6 73 41 23 70
600 45.7 71 25 20 68
Ordering Information
P/N Product Description P.U
60015820 ToughCat C7 LSHF-FR 4×2/0.27mm2 500m/drum
60030363 ToughCat C7 LSHF-FR 4×2/0.27mm2 1000m/drum

ICS IE ToughCat 5e LSHF-FR

S/FTP Installation Cable 4x2xAWG24/7 for tougher environments

Construction
Conductor Stranded copper wire, cross section 0.22 mm² (AWG24/7)
Insulation PE
Twisting 2 cores to the pair
Cable lay up 4 pairs
Pair screen Al-laminated plastic foil around each pair
Overall screen Copper braid, tinned
Sheath Oil resistant, Flame retardant and halogen free LSZH-FR (SHF1)
Colour Grey RAL 7035
Outer Diameter Nom. 7.7 mm
Weight Nom. 68 kg/km
Tensile force N 100
Mechanical properties
Bending radius Without load 8 x D
With load 4 x D
Temperature range During operation -40°C to + 85°C
During installation -15°C to + 50°C
Fire load 4 pair 670 MJ/km
Maximum tensile load During operation No load
During installation 100 N
Electrical properties at 20°C
DC Loop resistance ≤ 158 Ω/km
Resistance unbalance ≤ 2%
Insulation resistance (500 V) ≥ 5000 MΩxkm
Capacitance at 800 Hz Nom. 43 nF/km
Mean Characteristic impedance @ 100 MHz 100 Ω± 5 Ω
Nominal velocity of propagation 75%

Application

  • Generic Data transmission. This cable is a Cat5e S/FTP cable is meant for use as installation/horizontal cable in tougher electrical and mechanical environment,including ships and offshore units.

Standards

  • EN 50288-2-1
  • Det Norske Veritas(DNV GL) Class Program DNVGL-CP-0403 and Lloyd Register approval system 2002

Flame Rating

  • IEC 60332 – 1, IEC 60332-3-24

Chemical Resistance

  • Mineral oils IRM902(IEC 60811-2-1)
  • Diesel – IRM 903(IEC60811-2-1)

Certification

  • This cable is certified by :Det Norske Veritas(DNV) and Llyod Register
Electrical Data Nominal at 20°C
Freq. Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT
(MHZ) (dB/100m) (dB) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m)
1 2.1 90 88 87 85 85 82
4 4.0 90 86 27 87 83 85 82
10 6.3 90 84 30 87 81 79 76
16 8.0 90 82 30 87 79 75 72
20 9.0 90 81 30 87 78 73 70
31.25 11.4 90 79 30 87 76 69 66
62.50 16.50 86 70 30 83 67 63 60
100 21.3 83 62 30 80 59 59 56
Ordering Information
P/N Product Description P.U
60015830 ToughCat C5e LSHF-FR 4×2/0.22mm² 500DP 500m/drum
60015833 ToughCat C5e LSHF-FR 4×2/0.22mm² 1000DP 1000m/drum

Draka UC400 Cat.6 U/FTP 23AWG LSFRZH AR_AT_UV

Category cable for demanding environments

Application

  • Generic Data transmission. This cable is a Cat6 U/FTP cable is meant for use as installation/horizontal cable in demanding electrical and mechanical environment.

Standards

  • ANSI/TIA 568.2-D;
  • ISO/IEC 11801-1/2; IEC 61156 – 5
  • EN 50173; EN 50288-5-1

Flame Rating

  • IEC 60332-1, IEC 60332-3-24
Construction
Conductor Solid copper wire, (AWG23)
Insulation Foam PE
Twisting 2 cores to the pair
Pair Screen Individual Aluminium Foil Polyester Tape with drain wire
Outer Sheath LSFRZH. AR-AT-UV
Sheath Colour Black
Mechanical properties
Bending radius Installation 8 X D
Temperature range During operation -20°C to + 70°C
During installation 0°C to + 50°C
Maximum Pulling Force  During installation 100N
Electrical properties at 20°C
DC Loop resistance ≤ 187.6 Ω/km
DC Resistance unbalance ≤ 5%
Mutual capacitance at 1kHz ≤ 5.6nF/100m
Capacitance unbalance (pair/ground) ≤ 536 ns/100m
Velocity of Propagation Nom. 69%
Electrical Data at 20°C
Freq. Max. Attenuation Min.NEXT Min.PS-NEXT Min.Return Loss
(MHZ) (dB/100m) (dB) (dB) (dB)
1 2.0 74.3 72.3 20.0
4 3.8 65.3 63.3 23.0
16 7.6 56.2 54.2 25.0
25 9.5 53.3 51.3 24.3
62.5 15.4 47.7 45.7 21.5
100 19.8 44.3 42.3 20.1
200 29.0 39.8 37.8 18.0
250 32.8 38.3 36.3 17.3
Ordering Information
P/N Product Description P.U
66048RTVBK-5H Draka UCDATA CATEGORY CABLE UC400 CAT.6 UFTP 4 PAIR 23AWG LSFRZH ATARUV BLACK IEC60332-3-24, IEC60754-1&2, IEC 61034 500m/drum

Draka UC500 Cat.6a S/FTP SWB LSZH AR_AT_UV

Category cable for demanding environments

Construction
Conductor Solid copper wire (AWG23)
Insulation Foam PE
Twisting 2 cores to the pair
Pair Screen High Performance Individual Pair Screen
Overall screen Tinned Copper Braid
Inner Sheath LSZH
Armouring Galvanized Steel Wire Braid
Outer sheath LSZH (AR-AT-UV)
Sheath colour Black
Mechanical properties
Bending radius Installation (No Load) 8 x D
Temperature range During operation -20°C to + 70°C
During installation  0°C to + 50°C
Electrical properties at 20°C
DC Loop resistance ≤ 187.6Ω/km
DC Resistance Unbalance ≤ 4%
Characteristic impedance 1-100Mhz 100 ± 15 Ω
Mutual capacitance at 1kHz ≤ 5.6nF/100m
Capacitance unbalance (pair to ground) ≤ 300 pF/100m
Nom. Velocity of Propagation 76%

Application

  • Generic Data transmission. This cable is a Cat6a S/FTP cable is meant for use as installation/horizontal cable in demanding electrical and mechanical environment.
  • Suitable for installation in Anti-Termite, Anti-Rodent & UV Resistance area.

Standards

  • ANSI/TIA 568.2-D;
  • ISO/IEC 11801-1/2 ; IEC 61156 – 5
  • EN 50173; EN 50288- 5 -1

Flame Rating

  • IEC 60332 – 1
Electrical Data Nominal at 20°C
Freq. Max. Attenuation Min. Return loss Min. NEXT
(MHZ) (dB) (dB) (dB)
1 2.1 20 74.3
4 3.8 23 65.3
16 7.5 25 56.2
100 19.1 20.1 44.3
250 31.1 17.3 38.3
500 45.3 15.2 33.8
Ordering Information
P/N Product Description P.U
85075BRTVBK-5H Draka UCDATA CATEGORY CABLE UC500 CAT.6A SFTP 4 PAIR 23AWG GSWB Armoring LSZH ATARUV Black IEC60332-1, IEC 60754-1&2, IEC 61034 500m/drum