Security & Comms Cable, SXACS Series

Shielded, LSZH

 

 

Application

  • Security, Intercom, Broadcast, Sound, Audio Systems

Flame rating

  • LSZH IEC 60332-1
Construction
Conductor
Grade A Bare Copper, Stranded
Operating Voltage
300V
Insulation
XLPE
Insulation colour
1 - Black, 2 - Red, 3 - White, 4 - Green
1st Screen
100% Overall Aluminum Foil Screen
Sheath
LSZH with Ripcord
Sheath colour
Grey , Red
Rated temperature
Up to 75°C
Cable Dimension
Conductor Size No of Pairs OD (mm)
12 AWG 1 Pair 7.6
  2 Pairs 11.3
14 AWG 1 Pair 6.6
  2 Pairs 9.7
16 AWG 1 Pair 5.2
  2 Pairs 7.6
18 AWG 1 Pair 4.6
  2 Pairs 6.6
20 AWG 1 Pair 4.2
  2 Pairs 6.1
22 AWG 1 Pair 3.8
  2 Pairs 5.3
 
Ordering Information
SXACS Series part numbers are made up using the table below.
The part number starts with SXACS to denote that it is a SXACS cable.
The following number shows the number of pairs and the last 2 numbers signifies the AWG.
Any letter behind would describe the sheath type and colour.

Example of a SXACS part number-SXACS1P22LRD-3H
The above example describes SXACS cable with 1 pairing, 22 AWG. Sheath type LSZH.

 

SXACS PAIRING AWG SHEATH Colour Drum Length
SXACS X XX X X – X
  1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
20 – 20 AWG
22 – 22 AWG

L- LSZH

GY-Grey
RD- Red

 

-3H : 305m

-5H : 500m

 

Draka RS-485 22 AWG FPE

Serial Data Communication Cable

 
Construction
Conductor Stranded Tinned Copper
Insulation Foam PE
Colour Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange
Pair 3: 1 x white, 1 x black Pair 4: 1 x green
1st Screen 1 x AL-Mylar Wrap, overlapping ≥ 25 %
Drain Wire Stranded Tinned Copper
Braid Shield Tinned Copper ; coverage ≥ 85%
Sheath PVC/LSZH/LSZH ATARUV
Braid Armour (Optional) Galvanized Steel Wire Braid
Outer Sheath (Optional) LSZH / LSZH ATARUV
Pair 1P 2P 3P 4P
  Nom. Cable OD mm
TC/FPE/OS/TCWB/PVC 6.5 8.5 9.5 11.5
TC/FPE/OS/TCWB/LSZH 6.5 8.5 9.5 11.5
TC/FPE/OS/TCWB/LSZH ATARUV 6.5 8.5 9.5 11.5
TC/FPE/OS/TCWB/LSZH/SWB/LSZH 10.8 13.4 13.8 15.8
         
 

Application

  • For multi-dropped,medium-speed,serial data communication in electrically noisy industrial environments.Application includes industrial networks using RS-485/RS- 422/RS-232 transceivers, for Process Automation (chemicals, brewing, paper mills), factory automation (autos, metal fabrication), HVAC, security, motor control and motion control.Suitable for outdoor installation.

Flame Rating

  • IEC 60332 – 1
 
Electrical properties  
Conductor Resistance (at 20ºC)   ≤ 58 Ω/km  
Capacitance cond. to cond. Nom. 12.5 pF/ft  
Impedance Nom. 120 Ω  
Rated Voltage 300 V  
Mechanical properties  
Operating temperature -20°C to +70°C  
Bend Radius 10 x OD  
     
Ordering Information
RS-485  part numbers are made up using the table below.
The part number starts with 48 to denote that it is an EIA-485 cable.
The following number shows the number of pairing and the last 2 numbers signifies the AWG.

Example of an EIA-485 part number

48124LB 

The above example describes an RS-485 SWB cable with 1 pair, 24 AWG. Sheath type LSZH, SWB

 

RS- 485 PAIRING AWG SHEATH OUTER JACKET ADDITIVE  
48 X XX X X X  
 
1 - 1 Pair
2 - 2 Pair
4 - 4 Pair


22 -22 AWG

(nil) - PVC
L- LSZH

B - SWB
RTV- Anti-Rodent, Anti-Termite, UV Resistance  
 

UCFIBRE™® MTV SERIES

2-24 Cores, Indoor Tight Buffer Distribution Cable, PVC OFNR Sheath

 

Overview

One of the most widely used UCFIBRE™® Indoor cable, MTV series is excellent for indoor installation that provides a safe setup against flame propagation and its flexible, yet robust construction makes installation at ease.

Additional Options

  • Steel Wire Braiding for armouring protection

Features

  • Tight buffer: Each fibre is coated to 0.9mm with PVC
  • Strength Member : Aramid yarn
  • Outer Sheath: PVC UL1651
  • Suitable for indoor installation requiring flame retardant
Main Characteristics
Test Standard Value Sanction*
Short term tension IEC 60794-1-2-E1 660 N (2F-12F),
1200N (24F)
Fibre strain ≤ 0.6%,Δα reversible
Max operation tension IEC 60794-1-2-E1 198N (2F-12F),
340N (24F)
Fibre strain ≤ 0.2%,Δα ≤0.4 db (MM),  ≤0.3db (SM)
Crush (short term) IEC 60794-1-2-E3 1000 N / 100mm Δα ≤0.4 db (MM),  ≤0.3db (SM), no damage
Temperature range IEC 60794-1-2-F1 -20 -> +70°C Δα ≤ 0.6 dB /km(MM),
Δα ≤ 0.40dB/km (SM)

* value of multi mode fibres, all optical measurements perform at 1300nm
* value of single mode fibres, all optical measurements perform at 1550nm

Technical Data
No. of Fibres   2,4,6 8 12 24
Design   1×2,4,6 TB 1×8 TB 1×12 TB 1×24 TB
Tight buffer mm 0.9 ± 0.05 0.9 ± 0.05 0.9 ± 0.05 0.9 ± 0.05
Cable Nom. Diameter mm 4.8 5.4 6.2 8.8
Cable Nom. Weight kg/km 20 26 33 60
Min. bending radius   Without Tension
10 x Cable Ø
Under Maximum Tension
20 x Cable Ø
Temperature range °C
Installation
-10 -> +60
Transport. & Storage
-40 -> +70
Operation
-20  -> +70
Flame Retardant    UL 1651
Ordering Information
UCFIBRE™® MTV SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters MTV to denote that it is an UCFIBRE™® MTV SERIES FO cable. This is followed by 3 numbers which symbolizes the core quantity and then 2 letters yo denote the fibre type. Example of a UCFIBRE™® MTV SERIES FO Cable part number: MTV008M1 The above example describes an OM1(62.5Sum, Orange Sheath) UCFIBRE™® MTV SERIES FO Cable, with 8 cores.
 
MT SERIES CORE QUANTITY FIBRE TYPE
MTV XXX XX
 
002 – 2 CORES
004 – 4 CORES
006 – 6 CORES
008 – 8 CORES
012 – 12 CORES
SM – SINGEMODE, G652D, 9um (yellow sheath)
M1 – OM1, 62.5um (orange sheath)
M2 – OM2, 50um (orange sheath)
M3 – OM3, 50um (aqua sheath)
M4 – OM4, 50um (violet sheath)

MAX-FOH Flexible Speaker Cable, PAGAS Series

Shielded Public Address General Alarm, Data Cable, Fire Resistance

Construction
Conductor Grade A Copper specially protected by fire barrier tape to ensure circuit
Construction integrity in fire situations
Core Insulation Twisted pair for better signal transmission.
Overall Screen Aluminium Foil
Outer Sheath High temperature resistance PE
LSZH in accordance to IEC 61034, IEC 60754-1 & 2.
Main Characteristics
Nominal overall diameter mm 8.0 ±0.5
Nominal weight (completed cable) Kg/km 66
Min bending radius mm 60
Max pulling tension kgf 21
Max conductor resistance @ 20°C Ω/km 12.1
Min insulation resistance @ 20°C MΩ/km 2000
Dielectric withstand test kV/min 1/1
Technical Data
Size As in Technical Datasheet
Specification reference IEC 60332-1, IEC 60332-3A, IEC 60331, SS299 / BS
6387 CWZ
Conductor material mm Plain annealed copper wire to IEC
Max operating temperature °C 90
No of Wire / Wire Diameter mm As in Technical Datasheet
Conductor shape Circular stranded
Insulation Cross-linked PE, XLPE
Insulation thickness mm As in Technical Datasheet
Core Colour mm Black & White OR Black & Red


Application

  • Most widely used fire resistance speaker & Audio/Motor control cables, which is highly flexible due to the unique tubing design. Draka MAX-FOH Flexible speaker cables meets the stringent BS 6387 CWZ performance standards and can be used in all critical Public Address General Alarm Systems.

Fire Rating

  • Specification References: IEC60331, SS-299/BS6387 CWZ, EN 50200 (Class PH120) & EN 50200 Annex E
Ordering Information
P/N Product Description P.U
PAGAS1P15 MAXFOH™FlexiTube, 1Pr x 1.5mm2, PAGA Fire Res, Overall Screened, BS 6387, 60331, LSZH, Orange 500m/drum
PAGAS1P25 MAXFOH™FlexiTube, 1Pr x 2.5mm2, PAGA Fire Res, Overall Screened, BS 6387, 60331, LSZH, Orange 500m/drum
PAGAS1P40 MAXFOH™FlexiTube, 1Pr x 4mm2, PAGA Fire Res, Overall Screened, BS 6387, 60331, LSZH, Orange 500m/drum

RG214 Stranded BC 94% 97% SCB

50 Ohm Coaxial Cable

Application

  • Any device that functions as a transmitter or trans receiver tends to use 50 Ohm Coaxial Cable. Widely used for industrial and commercial two-way radio frequency applications (including radio, and telecommunications). Used for high-frequency signal transmission.
  • Suitable for high EMI environments.

Flame Rating

  • IEC 60332-1
Construction
Material Detail mm
Inner Conductor Stranded Bare Copper Braid 7 x 0.75
Dielectric Solid PE 7.25
First Shield 34 AWG Silver-plated Copper Braid (SCB) 94% coverage N.A
Second Shield 34 AWG Silver-plated Copper Braid (SCB) 97% coverage N.A
Jacket PVC / LSZH 10.80
Flame Performance IEC 60332-1 N.A
Bending Radius 10 x O.D.
Electrical Characteristics
Impedance, Ω 50 Ω± 3.0 Ohm
Capacitance, Nominal 101 Ω± 3 pF/m
Velocity of Propagation, % > 66 %
Maximum Operating Voltage VRMS 3.7 kV
Spark Test 5.0 kV
Ordering Information
P/N Product Description P.U
RG4157BK-5H RG214, Stranded BC. 94%/97% Silver Copper Braid, PVC, 50 Ohm 500m/reel
RG4257BK-5H RG214, Stranded BC. 94%/97% Silver Copper Braid, LSZH, 50 Ohm 500m/reel

RG11 CCS APA 60% ALB

75 Ohm Coaxial Cable

Application

  • RG11 75 Ohm coaxial is ideal if the device being connected is a receiver of some kind. This includes devices such as Satellite and Cable TV Receiver Boxes. Can expect distances of up to 610m.
  • Suitable for CATV applications.

Flame Rating

  • IEC 60332-1
Construction
Material Detail mm
Inner Conductor Copper Clad Steel (CCS) 1.63
Dielectric Foam PE 7.11
First Shield Aluminum/Polymer/Aluminum (APA) bonded N.A
Second Shield 34 AWG Aluminum Braid (ALB) 60% coverage N.A
Jacket PVC CMR / LSZH / PE 10.03
Flame Performance IEC 60332-1 N.A
Bending Radius 10 x O.D.
Electrical Characteristics
Impedance, Ω 75 Ω± 3.0 Ohm
Capacitance, Nominal 52 ± 3 pF/m
Velocity of Propagation, % > 83%
Return Loss 5 – 1000 MHz, ≥ 20dB
1000 – 3000 MHz , ≥ 20dB
Ordering Information
P/N Product Description P.U
RG1576BK-5H RG11, CCS, 60% Aluminum Braid, PVC CMR, 75 Ohm 500m/reel
RG1276BK-5H RG11, CCS, 60% Aluminum Braid, LSZH, 75 Ohm 500m/reel
RG1676BK-5H RG11, CCS, 60% Aluminum Braid, PE, 75 Ohm 500m/reel

RG6 CCS APA 60% ALB APA 40% ALB

75 Ohm Coaxial Cable

Application

  • RG6 75 Ohm coaxial is used for cable television, satellite television and cable modems. Can expect distances of about 305m – 457m.
  • Suitable for CATV applications.

Flame Rating

  • IEC 60332-1
Construction
Material Detail mm
Inner Conductor Copper Clad Steel (CCS) 1.02
Dielectric Foam PE 4.57
First Shield Aluminum/Polymer/Aluminum (APA) bonded N.A
Second Shield 34 AWG Aluminum Braid (ALB) 60% coverage N.A
Third Shield Aluminum/Polymer/Aluminum (APA) N.A
Fourth Shield 34AWG Aluminum Braid (ALB) 40% coverage N.A
Jacket PVC / PVC CM / LSZH 7.54
Flame Performance IEC 60332-1 N.A
Bending Radius 10 x O.D.
Electrical Characteristics
Impedance, Ω 75 ± 3.0 Ohm
Capacitance, Nominal 52 ± 3 pF/m
Velocity of Propagation, % > 83%
Return Loss 5 – 1000 MHz ≥ 20dB
1000 – 3000 MHz ≥20dB
Ordering Information
P/N Product Description P.U
RG6170BK-5H RG6, CCS, 60% Aluminum Braid, APA, 40% Aluminum Braid, PVC, 75 Ohm 500m/reel
RG6770BK-5H RG6, CCS, 60% Aluminum Braid, APA, 40% Aluminum Braid, PVC CM, 75 Ohm 500m/reel
RG6270BK-5H RG6, CCS, 60% Aluminum Braid, APA, 40% Aluminum Braid, LSZH, 75 Ohm 500m/reel

RG6 CCS APA 60% ALB

75 Ohm Coaxial Cable

Application

  • RG6 75 Ohm coaxial is used for cable television, satellite television and cable modems. Can expect distances of about 305m – 457m.
  • Suitable for CATV applications.

Flame Rating

  • IEC 60332-1
Construction
Material Detail mm
Inner Conductor Copper Clad Steel (CCS) 1.02
Dielectric Foam PE 4.57
First Shield Aluminum/Polymer/Aluminum (APA) bonded
Second Shield 34 AWG Aluminum Braid (ALB) 60% coverage N.A
Jacket PVC/ PVC CM / LSZH 6.93
Flame Performance IEC 60332-1 N.A
Bending Radius 10 x O.D.
Electrical Characteristics
Impedance, Ω 75 ± 3.0 Ohm
Capacitance, Nominal 52 ± 3 pF/m
Velocity of Propagation, % > 83%
Return Loss 5 – 1000 MHz ≥ 20dB
1000 – 3000 MHz ≥ 20dB
Ordering Information
P/N Product Description P.U
RG6776BK-5H RG6, CCS. 60% Aluminum Braid, PVC CMR, 75 Ohm 500m/reel
RG6276BK-5H RG6,CCS. 60% Aluminum Braid, LSZH, 75 Ohm 500m/reel
RG6176BK-5H RG6, CCS. 60% Aluminum Braid, PVC, 75 Ohm 500m/reel

RG59 CCS APA 65% ALB

75 Ohm Coaxial Cable

Application

  • RG59 75 Ohm coaxial is used to carry baseband video in closed-circuit television. expect to get a distance of about 225m – 305m.
  • Suitable for CATV applications.

Flame Rating

  • IEC 60332-1
Construction
Material Detail mm
Inner Conductor Copper Clad Steel (CCS) 0.81
Dielectric Foam PE 3.66
First Shield Aluminum/Polymer/Aluminum (APA) Bonded N.A
Second Shield 36 AWG Aluminum Braid (ALB) 65% coverage N.A
Jacket PVC / PVC CM / LSZH 6.00
Flame Performance IEC 60332-1 N.A
Bending Radius 10 x O.D.
Electrical Characteristics
Impedance, Ω 75 ± 3.0 Ohm
Capacitance, Nominal 52 ± 3 pF/m
Velocity of Propagation, % > 83%
Return Loss 5 – 1000 MHz ≥ 20dB
1000 – 3000 MHz ≥ 20dB
Ordering Information
P/N Product Description P.U
RG9175BK-5H RG59, CCS, 65% Aluminum Braid, PVC, 75 Ohm 500m/reel
RG9775BK-5H RG59, CCS, 65% Aluminum Braid, PVC CM, 75 Ohm 500m/reel
RG9275BK-5H RG59, CCS, 65% Aluminum Braid, LSZH, 75 Ohm 500m/reel

Fire Alarm Cable, FACS Series

Shielded, PVC CMR, PE, LSZH

Application

  • Widely used in indoor fire alarm, security alarm & Intercom system requiring flame retardancy properties.

Flame rating

  • NEC Article Type FPLR,CL3R, PVC CMR Rated comply to IEC 60332-1
  • LSZH IEC 60332-1
Construction
Conductor Grade A Bare Copper, Solid
Operating Voltage 300V
Insulation PVC
Insulation colour 1 – Black, 2 – Red, 3 – White, 4 – Green
1st Screen 100% Overall Aluminum Foil Screen
Sheath PVC-CMR or LSZH with Ripcord
Sheath colour PVC-CMR or LSZH RED
Rated temperature Up to 75°C
Cable Dimension
Conductor Size No of Pairs Nom. OD (mm)
12 AWG 1 Pair 6.5
2 Pairs 10.3
14 AWG 1 Pair 5.6
2 Pairs 8.9
16 AWG 1 Pair 4.8
2 Pairs 7.5
18 AWG 1 Pair 4.3
2 Pairs 6.7
Ordering Information
FACS 12-18 AWG part numbers are made up using the table below.
The part number starts with FACS to denote that it is a FACS cable.
Following number shows the number of pairing and the last 2 numbers signifies the AWG. 
Any letter behind would describe the sheath type & colour.

Example of a FACS part number-FACS1P18LRD
The above example describes an FACS cable with 1 pairing, 18 AWG. Sheath type LSZH with Red Jacket.

FACS PAIRING AWG SHEATH  Colour
FACS X XX X
1P – 1 Pair
2P – 2 Pairs
12 – 12 AWG
14 – 14 AWG
16 – 16 AWG
18 – 18 AWG
C – PVC-CMR
L- LSZH
RD- Red