Configuration | ||||
---|---|---|---|---|
No. of Flbers | 4,8,12,24 | 32 | 36,48,72 | |
Design (Elements x Fibre/Tube) | 6x4 | 6x8 | 6x12 | |
Loose Tube/Filler - ø | mm | Nom. 2.1 | Nom.2.1 | Nom. 2.1 |
CSM/sheath diameter | mm | Nom. 2.3 | Nom. 2.3 | Nom. 2.3 |
Outer sheath thickness | mm | Nom. 2.0 | ||
Cable Diameter | mm | Nom. 16.4 | Nom.16.4 | Nom. 16.4 |
Cable Weight | kg.km | 436 | 436 | 436 |
Max installation tension | N | 5000 | ||
Min. bending radius ( Without Tension) | mm | 15 x Cable ø | ||
Min. bending radius ( Under Max. Tension) | 25 x Cable ø |
Main Mechanical and Environmental characteristics | ||||
---|---|---|---|---|
Test | Standard | Specified value | Acceptance Criteria* | |
Max. Tension | IEC 60794-1-2-E1 | See Configuration |
Δ I/I fibre strain ≤ 0.6%, |
|
Crush | IEC 60794 1-2-E3 | 4000 N/100 mm; reversible |
Δα ≤ 0.15dB(SM), 0.3 dB (MM) |
|
Water penetration | IEC 60794 1-2-F5C | Sample=3m,water column=1m |
No water leakages after 24hours |
|
Temperature Range | Transportation & Storage | -40° C to +70 ° C | ||
Installation | -10° C to + 70° C | |||
Operation | -40° C to +70 ° C |
* Values for single-mode fibres, all optical measurements performed at 1550 nm
* Values for multi-mode fibres, all optical measurements performed at 1300 nm
Ordering Information |
---|
LTFPNWM SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters LTFPNWM to denote that it is a LTFPNWM SERIES FO Cable. Cable part number: LTFPNWM008M1 |
LTFIPNWM SERIES | Core Qty | FIBRE TYPE | |
LTFPNWM | XXX |
XX |
|
---|---|---|---|
012-12 CORES
016-16 CORES 024-24 CORES 048-48 CORES 096-96 CORES
|
SM-SINGLEMODE, G652D, 9µm |