UCFIBRE™® LTFMSMNWM Series

2-96 Cores SWA, Nylon + LSZH Sheath, Chemical/Corrosive Resistant

Features

  • Central strength member (CSM): glass fibre reinforced plastic material (FRP) with plastic coat when needed.
  • Tube:thermoplastic material, containing up to 12 optical fibres and filled with a suitable water tightness compound.
  • Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
  • Core Wrapping: polyester tape (jelly filled)
  • Inner Sheath: MDPE (P) or LSZH (M)
  • Inner Armour: Corrugated steel tape
  • Middle Sheath: HDPE (P) or LSZH (M)
  • Nylon sheath: Black Nylon Polyamide 12 (PA 12)
  • Outer Armour: Galvanized steel wire. WB jelly filled,
  • Outer Sheath: LSZH flame retardant to IEC 60332-3C
  • Suitable for Direct Buried, Rodent /Termites/Corrosive environment. Flame retardant to LSZH to IEC 60332-3C, 61034 & 60754-1&2
Main characteristics
Test Standard Value Sanction*
Max. installation
tension
IEC 60794-1-2-E1 6000 N No visible fibre strain,
Δα ≤ 0.05 dB
Crush IEC 60794-1-2-E3 400N / 100mm Δα ≤ 0.3 dB(MM), 0.05 dB(SM)
Impact IEC 60794-1-2-E4 30 Nm, 3 impacts, r=300mm Δα ≤ 0.3 dB(MM),
0.05 dB(SM)
Temperature Cycling EC 60794-1-2-F1 -3 0 -> +70°C Δα ≤ 0.3 dB/km(MM),
0.05 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour

*values for single-mode fibres, all optical measurements performed at 1550 nm
*values for multi-mode fibres, all optical measurements performed at 1300 nm

Overview

This cable is especially designed for harsh
environments. The double armour
combination of corrugated steel tape and
galvanized steel provide superior crush
protection to the fibers. Water tightness
compound within loose tube reinforced by
polyster tape and jelly protects the fibers
against chemical, corrosion and moisture.

Additional Options

  • IEC 60332-1, IEC 60332-24, IEC 61034-2, IEC 60754-1/2
Technical Data
No.of Flbres 2, 4, 8 6, 12 24, 36, 48 72 96
Design (Elements × Fibres per Tube) 5×4 5×6 5×12 6×12 8×12
Loose Tube / Filler – Ø mm
2.0 nominal
2.0 nominal 2.0 nominal
CSM/sheath diameter mm
1.5 nominal
2.2 nominal 2.0/3.5
Outer sheath thickness mm
0.8 nominal
0.8 nominal 0.8 nominal
Middle sheath thickness mm
1.0 nominal
1.0 nominal 1.0 nominal
Nylon sheath thickness mm
0.4 nominal
0.4 nominal 0.8 nominal
Galvanized steel wire mm
1.0 nominal
1.0 nominal 1.25 nominal
Outer sheath thickness mm
1.9 nominal
1.9 nominal 1.9 nominal
Cable Diameter mm
17.9 nominal
18.6 nominal 20.4 nominal
Cable Weight kg / km
523
559 709
Max installation tension N
6000
Min. bending radius mm
Without Tension
15 × Cable-Ø
Under Maximum Tension
25 × Cable-Ø
Temperature range °C
Installation
-5 -> +50;
Transport. & Storage
-40 -> +70 ;
Operation
-30 -> +70
Ordering Information
UCFIBREâ„¢ LTFMSMNWM SERIES FO Cable part numbers are made up using the table below.
The part number always starts with the letters LTFMSMNWM to denote that it is a UCFIBREâ„¢ LTFMSMNWM SERIES FO Cable. This is followed by 3 numbers
which symbolises the core quantity and then 2 letters to denote the fibre type.
Example of a UCFIBREâ„¢ LTFMSMNWM SERIES FO Cable part number:
LTFMSMNWM08M1
The above example describes an OM1 (62.5um, Orange Sheath) UCFIBREâ„¢ LTFMSMNWM SERIES FO Cable, with 8 cores.

LTFMSMNWM SERIES CORE QUANTITY
FIBRE TYPE
LTFMSMNWM XXX XX
002 – 2 CORES
004 – 4 CORES
006 – 6 CORES
008 – 8 CORES
012 – 12 CORES
024 – 24 CORES
036 – 36 CORES
048 – 48 CORES
072 – 72 CORES
096 – 96 CORES
SM – SINGLEMODE, G652D, 9um (yellow sheath)
M1 – OM1, 62.5um (orange sheath)
M2 – OM2, 50um (orange sheath)
M3 – OM3, 50um (aqua sheath)
M4 – OM4, 50um (aqua sheath)

UCFIBRE™® LTFMSMWM Series

2 ~ 96 Fibres, SWA, Heavy Armoured Cable, LSZH Sheath

Overview

This cable is especially designed for harsh
environments. The double armour
combination of corrugated steel tape and
galvanized steel provide superior crush
protection to the fibers. Water tightness
compound within loose tube reinforced by
polyster tape and jelly protects the fibers
against chemical, corrosion and moisture.

Additional Options

  • IEC 60332-1, IEC 60332-24, IEC 61034-2, IEC 60754-1/2

Features

  • Central strength member (CSM): glass fibre reinforced plastic material (FRP) with plastic coating when needed.
  • Tube:thermoplastic material, containing up to 12 optical fibres and filled with a suitable water tightness compound.
  • Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
  • Core Wrapping: polyester tape (jelly filled)
  • Inner Sheath: LSZH
  • Inner Armour: Corrugated steel tape
  • Middle Sheath:LSZH
  • Outer Armour: Galvanized steel wire. WB jelly filled, wrapped with cotton tape
  • Outer Sheath: LSZH
  • Suitable for Direct Buried, Rodent/Termite/Water/Chemical environment.Flame retardant to IEC 60332-3C. LSZH to IEC 61034 & IEC 60754-1&2.
Main characteristics
Test Standard Value Sanction*
Max. installation
tension
IEC 60794-1-2-E1 6000 N No visible fibre strain,
Δα ≤ 0.05 dB
Crush IEC 60794-1-2-E3 400N / 100mm Δα ≤ 0.3 dB(MM), 0.05 dB(SM)
Impact IEC 60794-1-2-E4 30 Nm, 3 impacts, r=300mm Δα ≤ 0.3 dB(MM), 0.05 dB(SM)
Temperature Cycling EC 60794-1-2-F1 -30 -> +70°C Δα ≤ 0.3 dB/km(MM),
0.05 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour

* Values for multi-mode fibres, all optical measurements performed at 1300 nm

*Values for single-mode fibres, all optical measurements performed at 1550 nm

Technical Data
No.of Flbres 12, 24 36,48 96
Design (Elements × Fibres per Tube) mm 6×6 6×12 8×12
Loose Tube / Filler – Ø mm 1.8 2.1 2.1
CSM/sheath diameter mm 2.0 2.3 2.2/3.7
Outer sheath thickness mm 1.5 nominal 1.5 nominal 1.5 nominal
Cable Diameter mm 9.9 nominal nominal 10.6 nominal 11.9 nominal
Cable Weight kg / km 87 99 119
Max installation tension N
1500
Min. bending radius mm
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range °C Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-30 -> +70
Ordering Information
UCFIBREâ„¢ LTFMSMWM SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters LTFMSMWM to denote that it is a UCFIBREâ„¢ LTFMSMWM SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a UCFIBREâ„¢ LTFMSMWM SERIES FO Cable part number:
LTFMSMWM08M1The above example describes an OM1 (62.5um, Orange Sheath) UCFIBREâ„¢ LTFMSMWM SERIES FO Cable, with 8 cores.

LTFMSMWM
SERIES
CORE QUANTITY
FIBRE TYPE
LTFMSMWM XXX XX
002 – 2 CORES
004 – 4 CORES
006 – 6 CORES
008 – 8 CORES
012 – 12 CORES
024 – 24 CORES
036 – 36 CORES
048 – 48 CORES
072 – 72 CORES
096 – 96 CORES
SM – SINGLEMODE, G652D, 9um (yellow sheath)
M1 – OM1, 62.5um (orange sheath)
M2 – OM2, 50um (orange sheath)
M3 – OM3, 50um (aqua sheath)
M4 – OM4, 50um (aqua sheath)

UCFIBRE™® LTFGP SERIES

12-96 Cores, Non Metallic Armoured Rodent Resistant Cable,PE Sheath

Features

  • Central strength member (CSM): glass fibre reinforced plastic material (FRP) with plastic coating when needed.
  • Tube:thermoplastic material, containing up to 12 optical fibres and filled with a suitable water tightness compound.
  • Stranding: The required numbers of elements (tubes or fillers) are SZ stranded around the central strength member.
  • Longitudinal Water Tightness: WB jelly and water blocking yarn (partial jelly filled).
  • Peripheral reinforcement: glass yarns.
  • PE Outer Sheath: HDPE with rodent repellent additive.
Main characteristics
Test Standard Value Sanction*
Max. installation
tension
IEC 60794-1-2-E1 1500 N fibre strain ≤ 0.33%,
Δα reversible
Crush(short term) IEC 60794-1-2-E3 1000N / 100mm Δα ≤ 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -3 0 -> +70°C Δα ≤ 0.3 dB/km(MM),
0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour

*values for single-mode fibres, all optical measurements performed at 1550 nm
*values for multi-mode fibres, all optical measurements performed at 1300 nm

Overview

LTZMSM Series o–ers better
mechanical protection than LTZSM
Series and is able to be deployed in
exposed environment over short
distances reducing the reliability of
ducts and hence better cost efficiency.

Additional Options

  • PE Sheath (LTZPSP Series)
  • Steel Wire Armouring
  • UV Resistance
  • Anti Rodent & Termite addictives
Technical Data
No.of Flbres 12, 24 36,48 96
Design (Elements × Fibres per Tube) mm 6×6 6×12 8×12
Loose Tube / Filler – Ø mm 1.8 2.1 2.1
CSM/sheath diameter mm 2.0 2.3 2.2/3.7
Outer sheath thickness mm 1.5 nominal 1.5 nominal 1.5 nominal
Cable Diameter mm 9.9 nominal nominal 10.6 nominal 11.9 nominal
Cable Weight kg / km 87 99 119
Max installation tension N
1500
Min. bending radius mm
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range °C Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-30 -> +70
Ordering Information
UCFIBREâ„¢ LTFGP SERIES FO Cable part numbers are made up using the table below.The part number always starts with the lettersLTFGP to denote that it is a UCFIBREâ„¢ LTFGP SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a UCFIBREâ„¢ LTFGP SERIES FO Cable part number:

LTFGP008M4

The above example describes an OM4 (50um, Orange Sheath) UCFIBREâ„¢ LTFGP SERIES FO Cable, with 8 cores.

LTFGP
SERIES
CORE QUANTITY
FIBRE TYPE
LTFGP XXX XX
012 – 12 CORES024 – 24 CORES036 – 36 CORES

048 – 48 CORES

096 – 96 CORES

SM – SINGLEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)

M3 – OM3, 50um (aqua sheath)

M4 – OM4, 50um (aqua sheath)

UCFIBRE™® LTZSM SERIES

12-96 Cores, Light Armoured Cable, LSZH Sheath


Overview

LTZSM Series is one of the most value
for cost UC FIBREâ„¢ cable which is able to
run outdoor into indoor premises with
protection against harsh elements
ie Water / UV / Mechanical stress,
while ensuring saftey fire standards
are in place.

Additional Options

  • PVC Sheath (LTZSV)
  • PE Sheath (LTZSP)
  • PE Sheath for outdoor applications
  • Steel Wire Braiding for armouring protection

Features

  • Central strength member (CSM):steel wire with plastic coating when needed
  • Tube:thermoplastic material, containing up to 12 optical fibres and filled with a suitable water tightness compound
  • Stranding:The required numbers of elements (tubes or fillers) are SZ stranded
    around the central strength member
  • Longitudinal Water Tightness:WB jelly and water blocking yarn (partial jelly filled)
  • Armour:corrugated steel tape
  • Outer Sheath:LSZH
  • Suitable for Duct Buried or Indoor/Outdoor Installation
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain ≤ 0.33%, Δα reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm Δα ≤ 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C Δα ≤ 0.3 dB/km(MM),
0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m,water=1m No water leakage after 24 hour

* Values for multi-mode fibres, all optical measurements performed at 1300 nm

* Values for single-mode fibres, all optical measurements performed at 1550 nm

Technical data
No. of Fibres 12, 24 36, 48 96
Design (Elements × Fibres per Tube) 6×6 6×12 8×12
Loose Tube / Filler – Ø mm 1.8 2.0 2.0
CSM/sheath diameter mm 2.0 2.2 2.0/3.5
Outer sheath thickness mm 1.8 nominal 1.8 nominal 1.8 nominal
Cable Diameter mm 10.7 nominal 11.3 nominal 12.6 nominal
Cable Weight kg / km 158 177 208
Max installation tension N 3000
Min. bending radius mm
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range °C Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-40 -> +70
Flame Retardant IEC 60332-3-24
Ordering Information
UCFIBREâ„¢ LTZMSM SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters LTZSM to denote that it is a UCFIBREâ„¢ LTZSM SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a UCFIBREâ„¢ LTZSM SERIES FO Cable part number:

LTZSM008M2

The above example describes an OM2 (50um, Orange Sheath) UCFIBREâ„¢ LTZSM SERIES FO Cable, with 8 cores.

LTZSM
SERIES
CORE QUANTITY
FIBRE TYPE
LTZSM XXX XX
012 – 12 CORES024 – 24 CORES036 – 36 CORES

048 – 48 CORES

096 – 96 CORES

SM – SINGLEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)

M3 – OM3, 50um (aqua sheath)

M4 – OM4, 50um (aqua sheath)

UCFIBRE™® LTZMSM SERIES

12-96 Cores, Double Sheath Armoured Cable, LSZH

Features

  • Central strength member:steel wire with plastic coating when needed
  • Tube:thermoplastic material, containing up to 12 optical fibres and filled with a suitable water tightness compound
  • Stranding:The required numbers of elements (tubes or fillers) are SZ stranded
    around the central strength member
  • Longitudinal Water Tightness:polyester tape (jelly filled)
  • Inner Sheath:LSZH
  • Armour:corrugated steel tape
  • Outer Sheath:LSZH. Flame Retardant to IEC 60332-3C
  • Suitable for Direct Buried or Indoor/Outdoor Installation.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain ≤ 0.33%,
Δα reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm Δα ≤ 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C Δα ≤ 0.3 dB/km(MM),
0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m,
water=1m
No water leakage after 24 hour

*values for single-mode fibres, all optical measurements performed at 1550 nm
*values for multi-mode fibres, all optical measurements performed at 1300 nm


Overview

LTZMSM Series o–ers better
mechanical protection than LTZSM
Series and is able to be deployed in
exposed environment over short
distances reducing the reliability of
ducts and hence better cost efficiency.

Additional Options

  • PE Sheath (LTZPSP Series)
  • Steel Wire Armouring
  • UV Resistance
  • Anti Rodent & Termite addictives
Technical data
No. of Fibres 12, 24 36, 48 96
Design (Elements × Fibres per Tube) 6×6 6×12 8×12
Loose Tube / Filler – Ø mm 1.8 2.0 2.0
CSM/sheath diameter mm 2.0 2.2 2.0/3.5
Inner sheath thickness mm 0.8 nominal 0.8 nominal 0.8 nominal
Outer sheath thickness mm 1.8 nominal 1.8 nominal 1.8 nominal
Cable Diameter mm 12.5 nominal 13.1 nominal 14.4 nominal
Cable Weight kg / km 210 232 270
Max installation tension N 3000
Min. bending radius mm
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range °C Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-40 -> +70
Flame Retardant IEC 60332-3-24
Ordering Information
UCFIBREâ„¢ LTZMSM SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters LTZMSM to denote that it is a UCFIBREâ„¢ LTZMSM SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a UCFIBREâ„¢ LTZMSM SERIES FO Cable part number:

LTZMSM008M2

The above example describes an OM2 (50um, Orange Sheath) UCFIBREâ„¢ LTZMSM SERIES FO Cable, with 8 cores.

LTZMSM SERIES CORE QUANTITY
FIBRE TYPE
LTZMSM XXX XX
012 – 12 CORES024 – 24 CORES036 – 36 CORES

048 – 48 CORES

096 – 96 CORES

SM – SINGLEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)

M3 – OM3, 50um (aqua sheath)

M4 – OM4, 50um (aqua sheath)

UCFIBRE™® UTM SERIES

2-12 Cores, Light Armoured, Uni-tube Cable, LSZH Sheath

Features

  • Unitube:thermoplastic material, containing up to 12 fibres and filled with a
    suitable water tightness compound
  • Peripheral Strength Elements:Aramid yarns
  • Armour:corrugated steel tape
  • Outer Sheath:LSZH in accordance to IEC 61034, IEC 60754-1 & 2
  • Suitable for Duct Buried or Indoor/Outdoor Installation
Main characteristics
Test Standard Value Sanction*
Maximum Tension at
installation (short term)
IEC 60794-1-2-E1 220N Δl/l fibre ≤ 0.6%,
Δα reversible
Tension opération max
(long term)
IEC 60794-1-2-E1 800 N Δl/l fibre ≤ 0.2%, Δα reversible
Crush (short/long term) IEC 60794-1-2-E3 1500N / 800N /
100mm
Δα ≤ 0.3 dB , cable integrity
Temperature range IEC 60794-1-2-F1 -20 -> +70°C Δα ≤ 0.3 dB /km

*values for single-mode fibres, all optical measurements performed at 1550 nm

*values for multi-mode fibres, all optical measurements performed at 1300 nm


Overview

UTM Series is excellent robust
installations that enables flexible
bending radius but till provide
adequate mechanical protection in
exposed installation environment,
ie factories, outside buildings
facilities.

Additional Options

  • PE Sheath (UT Series)
  • Steel Wire Braiding for armouring
    protection
  • UV Resistance
Technical data
No. of Fibres 2, 4, 6, 8, 12
Design 1×12
Loose Tube / Filler – Ø mm 3.0 nominal
Sheath thickness mm 1.5 nominal
Cable Diameter mm 8.1± 0.5
Cable Weight kg / km 80
Max installation tension N 1200
Min. bending radius mm
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range °C Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-20 -> +70
Flame Retardant
IEC 60332-3-24
Ordering Information
UCFIBREâ„¢ UTM SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters UTM to denote that it is a UCFIBREâ„¢ UTM SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a UCFIBREâ„¢ UTM SERIES FO Cable part number:

UTM006M2

The above example describes an OM2 (50um, Orange Sheath) UCFIBREâ„¢ UTM SERIES FO Cable, with 6 cores.

UTM SERIES CORE QUANTITY
FIBRE TYPE
UTM XXX XX
002 – 2 cores004 – 4 cores006 – 6 cores

008 – 8 cores

012 – 12 cores

SM – SINGEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)

M3 – OM3, 50um (aqua sheath)

M4 – OM4, 50um (aqua sheath)

UCFIBRE™® ZICM Series

Zipcord Interconnect Cable, LSZH Sheath

Features

  • Buffer Coating: : LSZH material, tight buffered fiber
  • Peripheral reinforcement : Aramid yarn
  • Sub-unit Sheath : LSZH & OFNR
  • Outer Sheath : LSZH, 1 ripcord beneath
  • Suitable for Duct Buried or Indoor/Outdoor Installation
Main characteristics
Test Standard Value Sanction*
Maximum Tension at
installation (short term)
IEC 60794-1-2-E1 220N Δl/l fibre ≤ 0.6%,
Δα reversible
Tension operation max IEC 60794-1-2-E1 66N Δl/l fibre ≤ 0.2%,
Δα ≤ 0.40 dB (MM),
≤ 0.30 dB (SM)
Crush IEC 60794-1-2-E3 350N / 100mm Δα ≤ 0.40 dB (MM),
≤ 0.30 dB (SM) , cable integrity

*values for single-mode fibres, all optical measurements performed at 1550 nm
*values for multi-mode fibres, all optical measurements performed at 1300 nm

Overview

UCFIBREâ„¢ zipcord fibre optical provides the durability and flexibility to all indoor applications with ruggardized properties, its LSZH properties ensure a safe flame propagation restrictions and is widely used in any zipcord interconnect applications.

Additional Options

  • Plenum or Riser
  • Duplex
Technical Data
No.of Flbres
2
Design
/
Buffer Diameter – Ø mm 0.6 ± 0.05 0.6 ± 0.05 0.9 ± 0.05 0.9 ± 0.05
Sub-unit Sheath thickness mm 0.25 nominal 0.3 nominal 0.35 nominal 0.5 nominal
Sub-unit Diameter mm 1.6 nominal 1.8 nominal 2.0 nominal 2.9 nominal
Outer Sheath thickness mm 0. 5 nominal 0.5 nominal 0. 5 nominal 0.5 nominal
Cable Diameter (H x W) mm 2.6 x 4.3 2.8 x 4.7 3.0 x 5.1 3.9 x 6.9
Cable Weight kg / km 12 14 17 28
Max installation tension N 220 220 220 220
Min. bending radius Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range °C
Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-20 -> +70
Flame Retardant
LSZH, IEC 60332-1, IEC60332-3-24
Ordering Information
UCFIBREâ„¢ Zipcord Interconnect FO part numbers are made up using the table below.The part number always starts with the letters ZICM to denote that it is a Zipcord Interconnect FO Cable with a LSZH sheath. This is followed by 1 number which symbolises the cable diameter, 2 numbers to respresent the number of cores and then 2 letters to denote the fibre type.Example of a ZICM part number: –

SICM02M1

The above example describes an OM1 (62.5um), Zipcord Interconnect FO Cable (LSZH jacketing), with 2.0mm cable diameter.

ZIPCORD INTERCONNECT SHEATH
CABLE DIAMETER
CORES QUANTITY
FIBER TYPE
Z IC M X 02 XX
LSZH 6 – 1.6mm2 – 2.0mm SM – SINGEMODE, G652D, 9um (yellow sheath)M7 – G657A2, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)

M2 – OM2, 50um (orange sheath, Bendbright)

M3 – OM3, 50um (aqua sheath, Bendbright)

M4 – OM4, 50um (aqua sheath, Bendbright)

UCFIBRE™® SICM Series

Interconnect 2.0mm, Simplex LSZH+OFNR

Overview

UCFIBREâ„¢ interconnect fibre optical provides the durability and flexibility to all indoor applications, its LSZH properties ensure a safe flame propagation restrictions and is widely used in any interconnect applications.

Aditional Option

  • Plenum or Riser
  • Duplex

Features

  • Tight buffer : LSZH, 0.85mm semi-tight buffered fiber
  • Peripheral Reinforcement : Aramid yarn
  • Outer Sheath : LSZH & OFNR
Main characteristics
Test Standard Value Sanction*
Maximum Tension at
installation (short term)
IEC 60794-1-2-E1 140N Δl/l fibre ≤ 0.6%,
Δα reversible
Tension operation max IEC 60794-1-2-E1 70N Δl/l fibre ≤ 0.3%,
Δα ≤ 0.30 dB;
Crush IEC 60794-1-2-E3 350N / 100mm Δα ≤ 0.30 dB(SM);
cable integrity

* Values for single-mode fibres, all optical measurements performed at 1550 nm

Technical Data
No.of Flbres
1
Design Simplex
Buffer Diameter – Ø mm 0.85 ± 0.05
Cable Diameter (A x B) mm 2.0 ± 0.1
Cable Weight Approx. kg / km 4
Min. bending radius
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range â—¦C
Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
-20 -> +70;
Flame Retardant
LSZH: UL c(UL) OFNR, IEC 60332-1, IEC60332-3-24
Ordering Information
UCFIBREâ„¢ Simplex Interconnect FO part numbers are made up using the table below.The part number always starts with the letters SICM to denote that it is a Simplex Interconnect FO Cable with a LSZH sheath. This is followed by 2 numbers which symbolises the cable diameter and then 2 letters to denote the fibre type.Example of a SICM part number: –

SICM02M3

The above example describes an OM3 (50um), Simplex Interconnect FO Cable (LSZH jacketing), with 2.0mm cable diameter.

SIMPLEX INTERCONNECT SHEATH
CABLE DIAMETER
FIBRE TYPE
B IC M 02 XX
LSZH 2.0mm SM – SINGEMODE, G652D, 9um (yellow sheath)
M7 – G657A2, 9um (yellow sheath)
M1 – OM1, 62.5um (orange sheath)
M2 – OM2, 50um (orange sheath, Bendbright)
M3 – OM3, 50um (aqua sheath, Bendbright)
M4 – OM4, 50um (aqua sheath, Bendbright)

UCFIBRE™® BICM Series

2, 4, 6, 8, 12 Fibres Interconnect cable, LSZH Jacket

Overview

Up to 12 250um fibres protected by aramid yarns and LSZH sheath for indoor applications whereby easy stripping of fibre when terminating is required.

Aditional Option

  • Plenum or Riser

Features

  • Fibre : 2-12 core 250um coloured fibers
  • Strength Member : Aramid yarn
  • Outer Sheath : LSZH compliant to IEC 61034, IEC 60754-1&2, IEC 60332-1 & 60332-3-24
Main characteristics
Test Standard Value Sanction*
Maximum Tension at
installation (short term)
IEC 60794-1-2-E1 220 N fibre strain ≤ 0.6%, Δα reversible
Crush(short term) IEC 60794-1-2-E3 500 N / 100mm Δα ≤ 0.3 dB (SM), 0.4 dB (MM),
no damage
Temperature range IEC 60794-1-2-F1 0 -> +70 Δα ≤ 0.3 dB /km (SM),
0.6 dB /km (MM)
Technical Data
No.of Flbres
2-12
Design 1 x 12 coloured Fibres
Outer sheath thickness mm 0.7 nominal
Cable Nominal Diameter mm 3.3 ± 0.15
Cable Weight kg / km 10
Max installation tension N 220
Max operation tension N 73
Min. bending radius mm
Without Tension
10 × Cable-Ø
Under Maximum Tension
20 × Cable-Ø
Temperature range â—¦C Installation
-10 -> +60;
Transport. & Storage
-40 -> +70 ;
Operation
0 -> +70;
Flame Retardant
IEC 60332-1, IEC 60332-3-24
Ordering Information
UCFIBREâ„¢ BICM SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters BICM to denote that it is a UCFIBREâ„¢ BICM SERIES FO Cable with a LSZH sheath. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a BICM part number: –

BICM002SM

The above example describes a singlemode (G652D, 9um) UCFIBREâ„¢ BICM SERIES FO Cable (LSZH jacketing), with 2 cores.

BARE FIBRE 250um INTERCONNECT SHEATH
CORE
QUANTITY
FIBRE TYPE
B IC M XXX XX
LSZH 002 – 2 cores004 – 4 cores006 – 6 cores

008 – 8 cores

012 – 12 cor

SM – SINGEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)

M3 – OM3, 50um (aqua sheath)

M4 – OM4, 50um (aqua sheath)

UCFIBRE™® MTC SERIES

36 & 48 Cores, COMPACT Indoor Tight Buffer Distribution Cable,LSZH Sheath

Overview

Compact design version of MT Series with reduced overall diameter for easier installation and space limitation environment.

Aditional Option

  • PVC Sheath
  • PE Sheath for outdoor applications
  • Steel Wire Braidling for armouring protection

Features

  • Tight buffer: Each fibre is coated to 0.9mm with LSZH
  • Strength Member: Aramid yarn
  • Core Wrapping: Polyester tape
  • Outer Sheath: LSZH compliant to IEC 61034, IEC 60754 – 1&2, IEC 60332 -1& 60332 –3- 24
  • Suitable for Indoor Flame Retardant Environment.
  • Up to 40% more compact & lighter than standard indoor types but with lesser tensile load.
Main Characteristics
Test Standard Value Sanction*
Maximum installation load (a few hours) IEC 60794-1-2-E1 1300 N (36F,48F) Fibre strain, ≤ 0.6%,∆α reversible
Short term tensile strength. (some days) IEC 60794-1-2-E1 1300 N (36F,48F) Fibre strain, ≤ 0.4%,∆α reversible
Max operation tension IEC 60794-1-2-E1 400 N (36F, 48F) Fibre strain, ≤ 0.2%,∆α≤ 0.4 db(MM), ≤0.30(SM)
Crush (short term) IEC 60794-1-2-E3 1000N/100mm ∆α ≤ 0.4 dB(MM), ≤0.30(SM), no damage
Temperature range IEC 60794-1-2-F1 -20->+70◦C ∆α≤ 0.6 dB/km(MM), ≤0.30 db/km(SM)

* Values for multi-mode fibres, all optical measurements performed at 1300 nm

Values for single-mode fibres, all optical measurements performed at 1550 nm

Technical Data:
No. of fibres 36 48
Design 6×6 TB 4×12 TB
Tight buffer Size mm 0.9±0.05 0.9±0.05
Outer sheath thickness mm 1.2 nominal 1.2 nominal
Cable Outer Diameter mm 11.0±1.5 12±1.5
Cable Weight mm 100 140
Min. bending radius Without Tension
10×Cable-Ф
Under Maximum Tension
20×Cable-Ф
Temperature range â—¦C
Installation
-10 – > + 60;
Transport & Storage
-40 – > + 70;
Operation -20->+70
Flame Retardant IEC 60332 – 3 -24(3C)
Ordering Information
UCFIBREâ„¢ MTC SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters MTC to denote that it is a UCFIBREâ„¢ MTC SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type.Example of a UCFIBREâ„¢ MTC SERIES FO Cable part number: MTC048M4 The above example describes an OM4 (50um, Aqua Sheath) UCFIBREâ„¢ MTC SERIES FO Cable, with 48 cores.

MTC SERIES CORE QUANTITY FIBRE TYPE
MTC XXX XX
036 – 36 CORES048 – 48 CORES

 

SM – SINGEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)M3 – OM3, 50um (aqua sheath)

M4 – OM4, 50um (aqua sheath)