MAX-FOH Flexible PAGA & Control Cable

Public Address General Alarm, Data Control Cable, Fire Resistance

Fire Characteristics
Conductor Grade A Copper specially protected by fire barrier tape to ensure circuit integrity in fire situations.
Construction Twisted pair for better signal transmission.
Core Insulation Cross-linked PE, XLPE
Outer Sheath LSZH in accordance to IEC 61034, IEC 60754-1 & 2.
Main Characteristics
Nominal overall diameter mm As per Technical Datasheet
Nominal weight (completed cable) Kg/km As per Technical Datasheet
Min bending radius mm As per Technical Datasheet
Max pulling tension kgf As per Technical Datasheet
Max conductor resistance @ 20°C Ω/km As per Technical Datasheet
Min insulation resistance @ 20°C MΩ/km As per Technical Datasheet
Dielectric withstand test kV/min As per Technical Datasheet
Technical Details
Size As per Technical Datasheet
Specification reference IEC 60332-1, IEC60332-3A, IEC 60331, BS
6387 CWZ
Conductor material mm Plain annealed copper wire to IEC
Max operating temperature °C 90
No of Wire / Wire Diameter mm As per Technical Datasheet
Conductor shape Circular stranded
Insulation Cross-linked PE, XLPE
Insulation thickness mm As per Technical Datasheet
Core Colour mm Black & White

Application

  • Most widely used fire resistance speaker & Audio/Motor control cables, which is highly flexible due to the unique tubing design. Draka MAX – FOH flexible speaker cables meets the stringent BS 6387 fire performance standards and can be used in all critical Public Address General Alarm Systems.

Fire Rating

  • Generally to :ISO/IEC 11801:95, IEC 61156, EN 50173:95; EN 50288-1,BS 6387
Ordering Information
P/N Product Description P.U
PAGA2C15 MAX-FOH FlexiTube, 2Cx1.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum
PAGA3C15 MAX-FOH FlexiTube, 3Cx1.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum
PAGA2C25 MAX-FOH FlexiTube, 2Cx2.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum
PAGA3C25 MAX-FOH FlexiTube, 3Cx2.5mm², PAGA Fire Res,

BS 6387, IEC 60331, LSZH, Orange

500m/drum

Draka Style 2919

Individual Pair Screened Control Cable

Application

  • For installation require flexible cable to fulfill measuring, controls & command applications. Example Computer Interconnection, Data Transmission, Control Circuits, Industrial Equipment Control, suitable for RS-485 applications.

Optional

  • PVC/Steel Wire Braid
  • High pair counts upon request.
Technical Details
Conductor Stranded Tinned Copper
Operating Voltage 300V
Insulation HD-PE/Foam-PE
Insulation colour Pair 1: White*Orange
1st screen 1 x AL-Mylar Wrap, overlapping >= 25 %
Drain wire 7/0.254mm Stranded Tinned Copper
Braid Shielding Tinned Copper Braid
Sheath LSZH
Sheath Colour Grey
Operating Temperature -20°C ~ +70°C
Cable Dimension
Conductor Size DC Resistance @ 20°C (Ω/km) No of Pairs Nom. OD (mm)
18 AWG <= 23.2 1 Pair 7.5
<= 23.2 2 Pairs 10.3
<= 23.2 4 Pairs 12.8
20 AWG <= 36.7 1 Pair 7.0
<= 36.7 2 Pairs 9.3
<= 36.7 4 Pairs 11.5
22 AWG <= 58.0 1 Pair 6.5
<= 58.0 2 Pairs 9.8
<= 58.0 4 Pairs 11.5
24 AWG <= 89.0 1 Pair 6.5
<= 89.0 2 Pairs 9.0
<= 89.0 4 Pairs 10.2
Ordering Information
Draka Style 2919 part numbers are made up using the table below.
The part number starts with 29 to denote that it is a UL 2919 cable.
The following number shows the number of pairing and the last 2 numbers signifies the AWG.
Any letter behind would describe the sheath & colour type.

Example of a Draka Style 2919 part number : 29418LGY




The above example describes an UL 2919 cable with 4 pairing, 18 AWG. Sheath type LSZH.

UL 2919 PAIRING AWG SHEATH  Colour
29 X XX X X
1 - 1 Pair
2 - 2 Pair
3 - 3 Pair
4 - 4 Pair
18 - 18 AWG
20 - 20 AWG
22 - 22 AWG
24 - 24 AWG
(nil) - PVC
L- LSZH
GY - GREY
BK- BLACK

Draka Style 2464

Overall Screened Data Control Cable

Technical Details
Conductor Stranded Tinned Copper
Operating Voltage 300V
Insulation SR-PVC
Insulation colour White/Brown, Green/Yellow, Gray/Pink, Blue/Red
Drain wire(Construction,mm) 7/0.254mm Stranded Tinned Copper
Screen Overall Foil Shield + Drain Wire
Sheath PVC/LSZH
Operating Temperature -20°C to +70°C
Cable Dimension
Conductor Size DC Resistance @
20°C (Ω/km)
No of Pairs Nom. OD (mm)
16 AWG ≤ 14.5 1 Pair 6.2
≤ 14.5 2 Pair 9.0
≤ 14.5 4 Pair 11.0
18 AWG ≤ 23.2 1 Pair 5.6
≤ 23.2 2 Pair 8.0
≤ 23.2 4 Pair 10.0
20 AWG ≤ 36.7 1 Pair 5.0
≤ 36.7 2 Pair 6.4
≤ 36.7 4 Pair 7.7
22 AWG ≤ 59.4 1 Pair 4.6
≤ 59.4 2 Pair 5.5
24 AWG ≤ 94.2 1 Pair 4.0
≤ 94.2 2 Pair 5.0
≤ 94.2 3 Pair 5.8
≤ 94.2 4 Pair 6.7

Application

  • For installation requiring flexible connector cable to fulfill measuring,controls & command applications. Example : Computer Interconnection,Data Transmission,Control Circuits,Industrial Equipment Control,suitable for EIA RS-232 applications.
Ordering Information
Draka Style 2464 part numbers are made up using the table below.
The part number starts with 24 to denote that it is an UL 2464 cable.
The following number shows the number of pairing and the last 2 numbers signifies the AWG.
The following letter describes the sheath type & colour.

Example of an UL 2464 part number -

24116GY

The above example describes an UL 2464 cable with 1 pair, 16 AWG. Sheath type PVC.

UL 2464 PAIRING AWG SHEATH Colour
24 X XX X X
1 - 1 Pair
2 - 2 Pair
3 - 3 Pair
4 - 4 Pair
16 - 16 AWG
18 - 18 AWG
20 - 20 AWG
22 - 22 AWG
(nil) - PVC
L- LSZH
GY-Grey

Draka RS-485 24 AWG FPE

Serial Data Communication Cable

Construction
Conductor Stranded Tinned Copper
Insulation Foam PE
Colour Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange
Pair 3: 1 x white, 1 x black Pair 4: 1 x green
1st Screen 1 x AL-Mylar Wrap, overlapping ≥ 25 %
Drain Wire Stranded Tinned Copper
Braid Shield Tinned Copper ; coverage ≥ 85%
Sheath PVC/LSZH/LSZH ATARUV
Braid Armour (Optional) Galvanized Steel Wire Braid
Outer Sheath (Optional) LSZH / LSZH ATARUV
Pair 1P 2P 3P 4P
Nom. Cable OD mm
TC/FPE/OS/TCWB/PVC 6.2 8.5 9.1 9.8
TC/FPE/OS/TCWB/LSZH 6.2 8.5 9.1 9.8
TC/FPE/OS/TCWB/LSZH ATARUV 6.2 8.5 9.1 9.8
TC/FPE/OS/TCWB/LSZH/SWB/LSZH 10.7 13.0 13.6 14.3

Application

  • For multi-dropped,medium-speed,serial data communication in electrically noisy industrial environments.Application includes industrial networks using RS-485/RS- 422/RS-232 transceivers, for Process Automation (chemicals, brewing, paper mills), factory automation (autos, metal fabrication), HVAC, security, motor control and motion control.Suitable for outdoor installation.

Flame Rating

  • IEC 60332 – 1
Electrical properties
Conductor Resistance (at 20ºC)   ≤ 89 Ω/km
Capacitance cond. to cond. Nom. 12.5 pF/ft
Impedance Nom. 120 Ω
Rated Voltage 300 V
Mechanical properties
Operating temperature -20°C to +70°C
Bend Radius 10 x OD
Ordering Information
RS-485  part numbers are made up using the table below.
The part number starts with 48 to denote that it is an EIA-485 cable.
The following number shows the number of pairing and the last 2 numbers signifies the AWG.

Example of an EIA-485 part number

48124LB 

The above example describes an RS-485 SWB cable with 1 pair, 24 AWG. Sheath type LSZH, SWB

RS- 485 PAIRING AWG SHEATH OUTER JACKET ADDITIVE
48 X XX X X X
1 - 1 Pair
2 - 2 Pair
4 - 4 Pair


24 -24 AWG

(nil) - PVC
L- LSZH

B - SWB
RTV- Anti-Rodent, Anti-Termite, UV Resistance

UCFIBRE™® MT SERIES

36,48,72,96 Cores, Indoor Tight Buffer Distribution Cable, LSZH

Features

  • Tight buffer: Each fibre is coated to 0.9mm with LSZH
  • Strength Member: Aramid yarn within each sub-unit
  • Sub-unit sheath: LSZH material
  • Central Strength Member: FRP with up-coating
  • Core Wrapping: Polyester tape
  • Outer Sheath: LSZH compliant to IEC 61034, IEC 60754-1 & 2, IEC 60332 -1 & 60332-3- 24
  • Suitable for Indoor Flame Retardant, Low Smoke and Halogen Free Environment
Main Characteristics
Test Standard Value Sanction*
Short Term Tensile Strength IEC 60794-1-2-E1 2800 N (36F,48F,72F), 4400N (96F) Fibre strain ≤ 0.4%, Δα reversible
Maximum installation tension IEC 60794-1-2-E1 1400 N (36F,48F,72F), 2200N (96F) Fibre strain ≤ 0.2%, Δα ≤ 0.4 dB (MM), ≤ 0.30 (SM)
Crush (short term) IEC 60794-1-2-E3 1000N/100mm Δα ≤0.4 db (MM),  ≤0.3db (SM), no damage
Temperature range IEC 60794-1-2-F1 -20ºC->+70ºC Δα ≤ 0.6 dB /km(MM), Δα ≤ 0.30dB/km (SM)

* Values for multi-mode fibres, all optical measurements performed at 1300 nm

* Values for single-mode fibres, all optical measurements performed at 1550 nm


Overview

One of the most widely used UCFIBRE™® Indoor cable, MT series is excellent for indoor installation that provides a safe setup against flame propagation and its flexible yet robust construction makes installation at ease.

Aditional Option

  • PVC Sheath for indoor applications
  • PE Sheath for outdoor applications
  • Steel Wire Braiding for armouring protection
Technical Data:
No. of fibres 36 48 96
Design 6×6 TB 4×12 TB 8×12 TB
Tight buffer mm 0.9 ± 0.05 0.9 ± 0.05 0.9 ± 0.05
Sub-unit Nom. Diameter mm 4.8 6.0 6.0
Cable Nominal Diameter mm 17.7±1.5 17.9±1.5 25.3±1.5
Cable Outer Diameter kg/km 276 244 538
Min. bending radius mm Without Tension, 10x Cable Ø
Under Maximum Tension, 20x Cable Ø
Temperature range °C Installation;
-10 – > + 60
Transport & Storage;
-40 – > + 70
Operation; -20->+70
Flame Retardant IEC 60332-3 -24

Please refer to our General Installation, Safety & Handling recommendations before handling.

Ordering Information
UCFIBRE™® MT SERIES FO Cable part numbers are made up using the table below.The part number always starts with the letters MB to denote that it is a UCFIBRE™® MT SERIES FO Cable.This is followed by 3 numbers which symbolizes the core quantity and then 2 letters to denote the fibre type. Example of UCFIBRE™® MT SERIES FO Cable part number: MT048M3 The above example describes an OM3(50UM, Aqua Sheath) UCFIBRE™® MT SERIES FO Cable, with 48 cores.

MT SERIES Core quantity FIBER TYPE
MT XXX XX
036 – 36 CORES048 – 48 CORES096 – 96 CORES
SM – SINGLEMODE, G652D, 9um (yellow sheath)M1 – OM1, 62.5um (orange sheath)M2 – OM2, 50um (orange sheath)M3 – OM3, 50um (aqua sheath)M4 – OM4, 50um (aqua sheath)